background image

8

5) GAS CONNECTION

The gas connection is located in the rear and on

the underside of the appliance 100 mm from the

right hand side.

There are two ways to carry out the connection to

the main gas line:

A. 

The hotplate can be connected with rigid pipe

as specified in AS5601 table 3.1.

B. 

If installing with a hose assembly, install with a

hose assembly that complies with AS/ANZ 1869

(AGA Approved), 10 mm ID, class B or D, no more

than 1.2 m long and in accordance with AS5601.

Ensure that the hose does not contact the hot

surfaces of the hotplate, oven, dishwasher or any

other appliance that may be installed underneath

or next to the hotplate. The hose should not be

subjected to abrasion, kinking or permanent

deformation and should be able to be inspected

along its entire length with the cooktop in the

installed position.

Unions compatible with the hose fittings must be

used and all connections tested for gas leaks.

The gas supply connection for the hose assembly

must be accessible.

Warning: 

ensure that the hose assembly is

restrained from accidental contact with the flue or

flue outlet of an underbench oven.

Natural Gas

Natural Gas installations require the connection of

a gas regulator at the appliance. This regulator is

supplied with the appliance on purchase.

Assemble the regulator (noting the gas flow

direction) and transition pieces (supplied with the

appliance), in accordance with figure 7.

The transition piece on the supply side of the

regulator must be provided by the installer.

Liquified Petroleum Gas

In a Propane Gas installation the gas regulation is

made at the gas cylinder and regulation at the

appliance is not required. To connect supply to the

appliance use transition pieces as shown in 

figure 8. These pieces are supplied with the

appliance on purchase.

WARNING:

THE BURNER FLAME MUST BE ADJUSTED BY

THE INSTALLER.

FAULTY  INSTALLATION  WILL  NOT  BE

COVERED UNDER WARRANTY.

THE  APPLIANCE  IS  FACTORY  SET  FOR

NATURAL GAS. THE TEST POINT PRESSURE

SHOULD BE ADJUSTED TO 1.00kPa WITH THE

WOK BURNER OPERATING AT MAXIMUM.

6) ELECTRICAL CONNECTION

The appliance is supplied with a 1800 mm long

flexible supply lead.

The point of attachment for this lead is located at

the rear and on the underside of the appliance

380 mm from the right hand side.

The voltage and power consumption are detailed

on the underside of the appliance. Ensure that the

appliance is correctly rated to the supply.

Connect appliance by way of a switched power

point.

THE APPLIANCE MUST BE EARTHED 

Ensure that this power point is properly earthed.

Look  at  the  connection  wiring  diagrams 

(fig. 9, 9/A and 9/B).

Warning:  in  order  to  avoid  hazard,  any

electrical work performed on this equipment or

its associated wiring, should only be done by

persons authorised by the supplier or similarly

qualified persons.

The socket outlet for this hotplate shall be

installed near the hotplate and shall be easily

accessible.

INSTALLATION

FIG. 7

FIG. 8

CAUTION!

The manufacturer cannot be responsible for

the missing earthing of the appliance.

Electrical connection must be carried out in

compliance with local regulations.

This appliance must be connected directly to

the mains supply.

Ensure the appliance is installed by an

authorised  person  in  accordance  with

AS/NZS 3000 wiring rules.

Summary of Contents for CGG302FFC

Page 1: ...ted at the back of this booklet COD 04067GGB 27 01 2011 Dear Customer Thank you for purchasing a Blanco Cooktop Before we continue telling you about this cooktop we cordially invite you to become part of the Blanco family by subscribing to ongoing information and invitations Please visit our website where you can subscribe and request such things as invitations to future cooking classes and gourme...

Page 2: ...MJ h 6 3 MJ h 5 Auxiliary gas burner 4 1 MJ h 3 6 MJ h 7 Cast iron trivet pan support 2F 8 Cast iron trivet pan support central 11 Burner n 1 control knob 12 Burner n 5 control knob 13 Burner n 4 control knob 14 Burner n 3 control knob 15 Burner n 2 control knob Attention this appliance has been manufactured for domestic use only Do not modify this appliance DESCRIPTION OF HOBS ...

Page 3: ...gnite the burners in a blackout situation Never leave the appliance unattended when the burners are being used Make sure there are no children in the near vicinity Particularly make sure that the pan handles are correctly positioned and keep a check on foods requiring oil and grease to cook since these products can easily catch fire The machine must not be used by people including children with im...

Page 4: ...g of the hob burner flame Sooting up of cooking utensils Burners not igniting properly Burners failing to remain alight Burner extinguished by cupboard doors Gas valves which are difficult to turn Do not place anything eg flame tamer asbestos mat between pan and pan support as serious damage to the appliance my result Do not remove the pan support and enclose the burner with a wok stand as this wi...

Page 5: ...ollowing instructions before remounting the parts check that burner head slots M fig 3 have not become clogged by foreign bodies Check that the enamelled burner cap C fig 3 has been correctly positioned on the burner head It must be steady Do not force the taps if they are difficult to open or close Contact an Authorised Service Centre for repairs Don t use steam jets for cleaning the cooktop FIG ...

Page 6: ...ound the various loose parts In case of doubt do not use the appliance and contact qualified personnel Never leave the packaging materials cardboard bags polystyrene foam nails etc within children s reach since they could become potential sources of danger The measurements of the opening made in the top of the modular cabinet and into which the hot plate will be installed are indicated in either f...

Page 7: ...g into place with the fingers and remove the strip of protective paper from the seal and set the plate into the hole made in the cabinet Position the hob in the hole in the unit and fasten it in place using the appropriate screws F and the fastening hooks G fig 6 When the appliance is installed so that the base can be touched we recommend fitting a protecting shield This shield must be at least 60...

Page 8: ...opane Gas installation the gas regulation is made at the gas cylinder and regulation at the appliance is not required To connect supply to the appliance use transition pieces as shown in figure 8 These pieces are supplied with the appliance on purchase WARNING THE BURNER FLAME MUST BE ADJUSTED BY THE INSTALLER FAULTY INSTALLATION WILL NOT BE COVERED UNDER WARRANTY THE APPLIANCE IS FACTORY SET FOR ...

Page 9: ...When satisfied with the hotplate please instruct the user on the correct method of operation In case the appliance fails to operate correctly after all checks have been carried out refer to the authorised service provider in your area 7 TAPS Our taps are suitable for all gas they are male conical type Reduced rate adjustment Switch on the burner and turn the relative knob to the Reduced rate posit...

Page 10: ... Appliance models Gas stainless steel hotplate models 1 Remove each burner cap and burner skirt 2 Remove the Natural Gas main injector with a 7 mm VF tube spanner and replace with the appropriate size Propane Gas main injector for each burner The following injector sizes are required for Propane Gas Burner Main injector Wok 2 x 0 72 B 0 50 B mm Rapid 0 91 mm Semi Rapid Reduced 0 60 mm Semi Rapid 0...

Page 11: ... supplied in the packet containing the spare injectors The envelope with the injectors and the labels can be included in the kit or at disposal to the authorised customer Service Centre For the sake of convenience the nominal rate chart also lists the heat inputs of the burners the diameter of the injectors and the working pressures of the various types of gas BURNER ARRANGEMENT ON THE HOT PLATE T...

Page 12: ...o ensure a perfect tightness Greasing the taps see fig 16 If a tap becomes stiff to operate it must be immediately greased in compliance with the following instructions remove the tap Clean the cone and its housing using a cloth soaked in diluent Lightly spread the cone with the relative grease Fit the cone back in place operate it several times and then remove it again Eliminate any excess grease...

Page 13: ...OF TYPE OF SINGLE PHASE HOT PLATE CABLE POWER SUPPLY CABLE TYPES AND SECTIONS ATTENTION If the power supply cable is replaced the installer should leave the ground wire longer than the phase conductors fig 17 and comply with the recommendations given in paragraph 6 13 ...

Page 14: ...LES Geebung QLD 4034 All General Whitegoods Telephone 07 3259 2555 Telephone 02 8788 8666 Facsimile 07 3265 6933 Facsimile 02 9752 5294 www agw com au VICTORIA AUSTRALIAN CAPATIAL TERRITORY Melbourne Showroom 35 Centre Road Detlevs Appliance Electrical Care Scoresby Telephone 02 6260 1033 VIC 3179 Facsimile 02 6260 1035 Telephone 03 8756 7888 Facsimile 03 8756 7907 VICTORIA South Australia Showroo...

Page 15: ... relevant standards Only a licenced person will have insurance protecting their workmanship for 6 years Make sure you use a licenced person to install this product and ask for your Compliance Certificate 1 The Warranty only applies provided that the appliance has been used in accordance with the manufacturer s instructions and provided that the appliance has not been damaged by an accident misuse ...

Page 16: ...16 ...