background image

15

SERVICING

TYPE OF

TYPE OF

SINGLE - PHASE

HOT PLATE

CABLE

POWER SUPPLY

CABLE TYPES AND SECTIONS

ATTENTION!!!

If the power supply cable is replaced, the installer should leave the ground wire longer than the phase

conductors (fig. 22) and comply with the recommendations given in paragraph 6.

FIG. 22

H05 RR - F

Section 3 X 0.75 mm

2

Gas hot plate

Summary of Contents for CG905WXC

Page 1: ...et COD 04031GGB 14 05 2010 Dear Customer Thank you for purchasing a Blanco Cooktop Before we continue telling you about this cooktop we cordially invite you to become part of the Blanco family by subs...

Page 2: ...s burner 4 1 MJ 3 5 MJ 5 Cast iron pan support 1F 6 Cast iron pan support 2F right 7 Cast iron pan support 2F left 8 Burner n 1 control knob 9 Burner n 2 control knob 10 Burner n 3 control knob 11 Bur...

Page 3: ...ame fig 1 Always place a lid on the pans Use only pan with a flat bottom and in thick metal WARNINGS Burners with flame failure device may only be ignited when the relative knob has been set to the Fu...

Page 4: ...iance may require additional ventilation This can be achieved by opening a window or by increasing the power of the mechanical exhausting system if installed Abnormal Operation Any of the following ar...

Page 5: ...s the side edge of the hot plate Do not force the taps if they are difficult to open or close Contact the technical assistance service for repairs Don t use steam jets for cleaning the cooktop CARE MA...

Page 6: ...struction shall be within 450mm above the top of the burner A minimum depth of 60mm from the top of the worktop surface must be provided for the appliance 3 INSTALLING THE HOT PLATE Check that the app...

Page 7: ...x the seal to the hot plate pressing into place with the fingers and remove the strip of protective paper from the seal and set the plate into the hole made in the cabinet Fix the hob with the proper...

Page 8: ...point is accessible with the appliance installed Warning Ensure that the hose assembly is restrained from accidental contact with the flue or flue outlet of an underbench oven Natural Gas Natural Gas...

Page 9: ...he appliance is correctly rated to the supply Connect appliance by way of a switched power point THE APPLIANCE MUST BE EARTHED Ensure that this power point is properly earthed Look at the connection w...

Page 10: ...sfied with the hotplate please instruct the user on the correct method of operation In case the appliance fails to operate correctly after all checks have been carried out refer to the authorised serv...

Page 11: ...opane Gas test point inlet fitting from the appliance 6 Fit the Natural Gas Regulator supplied in the conversion kit 7 Connect the gas supply to the Regulator 8 Check for gas leaks Do not use a naked...

Page 12: ...or fully clockwise 4 Shut off gas supply to the appliance 5 Disconnect gas inlet pipe from the Natural Gas Regulator 6 Remove the Natural Gas Regulator from the appliance 7 Fit the Propane Gas test po...

Page 13: ...OMINAL HEAT INPUT MJ h MAX BY PASS N DESCRIPTION 1 100 mm 1 ULTRA RAPID PROPANE NATURAL 2 75 1 00 94 176 14 5 11 4 85 1 2 2 RAPID PROPANE NATURAL 2 75 1 00 91 155 12 0 10 4 45 1 4 3 SEMIRAPID RIGHT FR...

Page 14: ...g 19 It is advisable to change seal D each time a tap is changed in order to ensure a perfect tightness Greasing the taps see fig 20 21 If a tap becomes stiff to operate it must be immediately greased...

Page 15: ...PLY CABLE TYPES AND SECTIONS ATTENTION If the power supply cable is replaced the installer should leave the ground wire longer than the phase conductors fig 22 and comply with the recommendations give...

Page 16: ...avour Appliances Telephone 07 3137 3633 Facsimile 07 3137 3663 Platinum Appliance Service Telephone 07 3862 1154 Facsimile 07 3862 1114 Roshad Gold Coast Telephone 07 5535 7044 Facsimile 07 5535 7407...

Page 17: ...relevant standards Only a licenced person will have insurance protecting their workmanship for 6 years Make sure you use a licenced person to install this product and ask for your Compliance Certifica...

Page 18: ...18...