on the worktop by means of the 4 brackets provided, taking the thickness of the worktop into ac-
count (Fig.1A). If the lower part of the appliance, after installation, is accessible via the lower part
of the cabinet then it is necessary to mount a separator panel respecting the distances indicated
(Fig.1C). If the appliance is installed with an oven underneath then the separator is not necessary.
• Electrical connections (Fig.2)
Before making the electrical connections, check that:
- the ground cable is 2 cm longer than the other cables;
- the system ratings meet the ratings indicated on the identification plate fixed on the lower part
of the worktop;
- the system is fitted with efficient earthing compliant to the laws and regulations in force.
Earthing is obligatory by law.
If the appliance is not fitted with a cable, use type:
“H05V2V2-F”
for a power level of up to 6400 Watts, the cross-section of the cable should be at least
2.5 mm², or 4 mm² for greater power levels.
The appliance is designed for permanent connection to the electricity supply and should therefore
be fitted with an omnipolar switch which has a minimum opening of 3 mm between contacts. The
switch should be suitable for the charge indicated on the appliance data plate and must conform
to all current legislation (the yellow/green earth wire must not be interrupted by the switch).
The omnipolar switch must be easy to reach once the installation process has been completed.
- If the electrical supply is restricted, means of all-pole disconnection must be accessible and incor-
porated in the fixed wiring in accordance with the wiring rules
- 6 -