Blanco BRC90BX Use And Care And Installation Instructions Download Page 7

When incorporating a rangehood in the design of a kitchen the following points need to be considered
to achieve the most benefit from the rangehood.

1. Ducting from a rangehood carrying the exhaust air, should not exceed a length of three (3) metres.
2. For ducted installation we recommend using galvanised or similar metal type flue pipe. PVC pipe is not
recommended.
3. Ducting containing a 90° degree bend will encounter a loss in efficiency of approximately 35%. Additional
90° degree bends can cause losses of up to 15% per bend.
4. Ducting size should always comply with the manufacturers specification.
5. We recommend carbon filters be used when re-circulating the air into the room. There will be some loss of
air movement when carbon filters are fitted.

USE AND MAINTENANCE

• It is recommended to operate the appliance prior to cooking.
It is recommended to leave the appliance in operation for 15 minutes after cooking is terminated in order to
minimise cooking vapours and odours.
The proper function of the cooker hood is conditioned by the regularity of the maintenance operations, in
particular, the active carbon filter.
• The aluminium grease filters capture the grease particles suspended in the air. The filters are therefore
subject to clogging according to the frequency of the use of the appliance.
In order to prevent a fire hazard, it is recommended to clean the filters every 2 months by carrying out the
following instructions:
- Remove the aluminium filters from the range hood and wash them in a solution of water and neutral liquid
detergent, leave to soak.
- Rinse thoroughly with warm water and leave to dry.
- The filters may also be washed in the dishwasher.
The aluminium filters may alter in colour after several washes. This is not cause for customer complaint nor
replacement of panels.

Recirculated to kitchen area via bulkhead

         Recirculated to kitchen area via ceiling cavity

Ducted to atmosphere through wall

         Ducted to atmosphere through roof

Summary of Contents for BRC90BX

Page 1: ...Instructions for the Use and Care and Installation of BRC90BX BRCG90BX BWCG90X BWGG90X BWC90X BWC9X BWC6X BWCS120X Rangehood...

Page 2: ...now has a range of laundry products to choose from Of course we make every effort to ensure that our products meet all your requirements and our Customer Service Department is at your disposal to ans...

Page 3: ...A 235 20 A B A A A B C max 90 cm Fig 1 Fig 2 Fig 3 Fig 4 Fig 5 A B...

Page 4: ...A G B C D E A A B C D E Fig 6 Fig 7 Fig 8 Fig 9 Fig 10...

Page 5: ...ighting or adjacent areas when lighting is on and for a period of time after using the light H Avoid leaving cooktop on gas and electric without the saucepan covering the burner or cooking zone This i...

Page 6: ...nce has been adjusted definitely fix the hood using the screws A Fig 5 For the various installations use screws and screw anchors suited to the type of wall e g reinforced concrete plasterboard etc If...

Page 7: ...operation for 15 minutes after cooking is terminated in order to minimise cooking vapours and odours The proper function of the cooker hood is conditioned by the regularity of the maintenance operatio...

Page 8: ...ed Display C indicates the motor speed level selected and activates the timer Push button D switches on the rangehood Increases the motor speed Touching the key at 3rd speed the intensive function run...

Page 9: ...Parts Endeavour Appliances Telephone 07 3872 7444 Facsimile 07 3852 2465 Platinum Appliance Service Telephone 07 3862 1154 Facsimile 07 3862 1114 Roshad Gold Coast Telephone 07 5535 7044 Facsimile 07...

Page 10: ...only applies provided that the appliance has been used in accordance with the manufacturer s instructions and provided that the appliance has not been damaged by an accident misuse neglect or abuse of...

Page 11: ...252...

Page 12: ......

Page 13: ......

Reviews: