background image

9

Always disconnect the appliance from the
electricity main before making any adjustments.
All seals must be replaced by the technician at
the end of any adjustments or regulations.
Our burners do not require primary air
adjustment.
a) Data Label

The Data Label is located on the underside of the
hotplate. A duplicate Data Label is supplied to adhere
in an accessible area next to the hotplate. This
hotplate is suitable for Natural Gas and U-LPG;
ensure that the available gas supply matches the
Data Label.

b) Before Leaving

Check that there are no gas leaks, but do not use a
naked flame to detect gas leaks. Ignite all burners to
ensure correct operation of gas valves, burners,
ignition and if fitted, flame failure valves. Turn gas
taps to low flame position and observe stability of the
flame. When satisfied with the hotplate, please
instruct the user on the correct method of operation.
In case the appliance falls to operate correctly after
all checks have been carried out, refer to the
authorised service provider in your area.

7) TAPS

Our taps are suitable for all the gas, they are male
conical type at one way.

“Reduced rate” adjustment 

- Switch on the burner and turn the relative knob to

the “Reduced rate” position (small flame fig. 1).

- Remove knob “M” (fig. 13 - 14) of the tap, which is

simply pressed on to its rod.

- Insert a small screwdriver “D” into hole “C”

(fig. 13 - 14) and turn the throttle screw to the right
or left until the burner flame has been adequately
regulated to the “Reduced rate” position. 

Check that the flame does not go out when the knob
is sharply switched from the “Full on” to the “Reduced
rate” position.

It is understood that only burners operating with
Natural gas should be subjected to the above
mentioned adjustments. The screw must be fully
locked when the burners operate with Liquid gas.

ADJUSTMENTS

FIG. 13

FIG. 14

TAPS WITH SAFETY VALVE

TAPS WITHOUT SAFETY VALVE

Summary of Contents for BCGR75

Page 1: ...k of this booklet COD 04010BLA 23 06 2004 Dear Customer Thank you for purchasing a Blanco Cooktop Before we continue telling you about this cooktop we cordially invite you to become part of the Blanco...

Page 2: ...lled steel pan support 2F right 6 Enamelled steel pan support 2F left 7 Central enamelled steel pan support for ultra rapid burner 8 Burner n 1 control knob 9 Burner n 2 control knob 10 Burner n 3 con...

Page 3: ...cy with the least possible gas consumption Use adequate pans for each burner consult the following table and fig 2 When the pan comes to the boil set the knob to the reduced rate position small flame...

Page 4: ...iance may require additional ventilation This can be achieved by opening a window or by increasing the power of the mechanical exhausting system if installed Abnormal Operation Any of the following ar...

Page 5: ...t towards the side edge of the hot plate Do not force the taps if they are difficult to open or close Contact the technical assistance service for repairs Don t use steam jets for cleaning the cooktop...

Page 6: ...packaging and internal wrappings from around the various loose parts In case of doubt do not use the appliance and contact qualified personnel Never leave the packacing materials cardboard bags polyst...

Page 7: ...r from the seal and set the plate into the hole made in the cabinet Fix the hob with the proper brackets S and fit the prominent part into the porthole H on the bottom turn the screw F until the brack...

Page 8: ...ied with the appliance on purchase Assemble the regulator noting the gas flow direction and transition pieces supplied with the appliance in accordance with figure 10 The transition piece on the suppl...

Page 9: ...truct the user on the correct method of operation In case the appliance falls to operate correctly after all checks have been carried out refer to the authorised service provider in your area 7 TAPS O...

Page 10: ...pplied in the conversion kit 7 Connect the gas supply to the Regulator 8 Check for gas leaks Do not use a naked flame to check for gas leaks 9 Adjust the gas pressure to 1 00 kPa with the wok burner o...

Page 11: ...ss injector fully clockwise 4 Shut off gas supply to the appliance 5 Disconnect gas inlet pipe from the Natural Gas Regulator 6 Remove the Natural Gas Regulator from the appliance 7 Fit the U LPG test...

Page 12: ...00 155 11 9 U LPG 2 75 91 10 8 NATURAL 1 00 145 10 4 U LPG 2 75 70 6 3 NATURAL 1 00 112 6 3 BURNERS N DESCRIPTION GAS NORMAL PRESSURE INJECTOR DIAMETER NOMINAL HEAT INPUT MJ h kPa 1 100 mm MAX TABLE...

Page 13: ...cal components can all be replaced fig 19 It is advisable to change seal D each time a tap is changed in order to ensure a perfect tightness Greasing the taps see fig 20 21 If a tap becomes stiff to o...

Page 14: ...LY CABLE TYPES AND SECTIONS ATTENTION If the power supply cable is replaced the installer should leave the ground wire longer than the phase conductors fig 22 and comply with the recommendations given...