background image

11

CONVERSIONS

FIG. 14

BURNER ARRANGEMENT ON THE HOT PLATE

U-LPG

2.75

95

11.9

NATURAL

1.00

155

11.9

U-LPG

2.75

70

6.3

NATURAL

1.00

112

6.3

BURNERS

N°          DESCRIPTION

GAS

NORMAL

PRESSURE

INJECTOR

DIAMETER

NOMINAL HEAT

INPUT (MJ/h)

(kPa)

(1/100 mm)

MAX.

TABLE

U-LPG

2.75

53

3.6

NATURAL

1.00

85

3.6

1

ULTRA RAPID

2

SEMIRAPID 

3

AUXILIARY

Summary of Contents for BCGC74 - BCGC52

Page 1: ...f this booklet COD 01019GG 26 07 2004 Dear Customer Thank you for purchasing a Blanco Cooktop Before we continue telling you about this cooktop we cordially invite you to become part of the Blanco fam...

Page 2: ...MJ 6 3 MJ 3 Auxiliary gas burner of 3 6 MJ 3 6 MJ 4 Cast iron trivet 1 burner 5 Cast iron trivet 2 burner 6 Cast iron trivet 3 burner 7 Burner control knobs Attention this appliance has been manufactu...

Page 3: ...light a burner if the flame divider Burner Cap is not correctly placed In the event of burner flames being accidentally extinguished turn off the burner control and do not attempt to re ignite the bur...

Page 4: ...w or by increasing the power of the mechanical exhausting system if installed Star Trivet use star trivet whenever using a small pot Abnormal Operation Any of the following are considered to be abnorm...

Page 5: ...r head slots M fig 6 have not become clogged by foreign bodies Check that enamelled burner cap C fig 6 have correctly positioned on the burner head It must be steady The exact position of the pan supp...

Page 6: ...stible material for a height of 150 mm for the entire length of the hob Any combustible construction above the hotplate must be at least 600 mm above the construction above the top of the burner and n...

Page 7: ...kinkingorpermanentdeformationand should be able to be inspected along its entire length with the cooktopintheinstalledposition Unions compatible with the hose fittings must be used and allconnectionst...

Page 8: ...underside of the appliance 380 mm from the right hand side The voltage and power consumption are detailed on the underside of the appliance Ensure that the appliance is correctly rated to the supply C...

Page 9: ...hen satisfied with the hotplate please instruct the user on the correct method of operation In case the appliance falls to operate correctly after all checks have been carried out refer to the authori...

Page 10: ...ly for use with U LPG label adhered to the bottom panel near the gas connection 10 NATURAL GAS TO UNIVERSAL LPG CONVERSION PROCEDURE Appliance models Gas crystal glass hotplate models BCGC74 4 Burners...

Page 11: ...LPG 2 75 95 11 9 NATURAL 1 00 155 11 9 U LPG 2 75 70 6 3 NATURAL 1 00 112 6 3 BURNERS N DESCRIPTION GAS NORMAL PRESSURE INJECTOR DIAMETER NOMINAL HEAT INPUT MJ h kPa 1 100 mm MAX TABLE U LPG 2 75 53 3...

Page 12: ...g 18 It is advisable to change seal D each time a tap is changed in order to ensure a perfect tightness Greasing the taps see fig 19 20 If a tap becomes stiff to operate it must be immediately greased...

Page 13: ...LY CABLE TYPES AND SECTIONS ATTENTION If the power supply cable is replaced the installer should leave the ground wire longer than the phase conductors fig 21 and comply with the recommendations given...

Reviews: