3.

 Feed folded end of strap through centre of first ratchet spindle as shown. Pull strap back so that folded end acts as

a hook. Feed other end of strap through centre of second ratchet spindle and fold back through lever as shown.

Operate  this ratchet to tighten. Remove any slack on the strap with the first ratchet. Tighten strap by operating both

ratchets alternately ensuring that strap stays horizontal around chimney. For final tightening, position ratchet handle

in open position as shown and push with the palm of the hand rather than pulling from the closed position. Fold levers

flat when finished. If the strap needs to be loosened for re-positioning, the ratchets may be released by pulling back

the spring loaded release levers in the handles.

SS/BKT14

Installation guide

SS/BKT14

Further advice may be downloaded from:
www.blake-uk.com/downloads on the following:

n

reception problems

n

fitting coaxial connectors

n

distributing TV signals around the home

n

general recommendations

Safety

Working at height – carry out work outdoors at height only if you are competent in the use of ladders and related access equipment.

Always work safely within your own limitations, ensuring that all equipment used is appropriate and is in good condition.

1.

 Fold back one end of strap as shown and pinch flat

with pliers.

2.

  Pass  strap  around  chimney  and  cut  to  size  allowing  a

10 cm (4”) overlap on each end (this will be taken up when

operating ratchets). To assist passing the strap around a

larger chimney, pre-feed strap into a short section of 1.25”

mast then using a ’fishing rod’ action, encircle chimney.

Pull off masting to leave strap in position.

25 mm 

(1”)

Accessories for use with this bracket (not included):

SS/STRAP/5M 

- 5m Individual Strapping Coil

SS/DISP100 

- 100m Roll Strapping Dispenser Pack

AC2

 1.75” V Bolts & 

AC4 

2.5” V Bolts.

Fit a suitable aerial mast to the bracket using V bolts. It may be

necessary to use a cranked mast if the chimney has a stepped top

(avoid positioning the aerial over the top of an operating chimney as

heat and gas may affect performance over time).
Maximum  recommended  length  of  aerial  -  2  metres;  maximum

recommended mast length - 10 ft  (3 metres). For heavier installations

use multiple products.
Do not install this product on a chimney which is in poor condition

(loose  or  damaged,  cracked  or  heavily  weathered  bricks).  For

stability, do not use the top three courses of chimney brickwork.

keep this

length short

release lever