For permanent installations to the mains supply, it is necessary to conform to the regulations of the local 
electricity authority and this would include the use of a metal or plastic conduit to protect the cable.

Attention has been drawn to the fact that special rules may exist concerning the installation of your 
pond UVC (i.e. local building regulations).

This UVC must not be used in swimming pools, or areas where people are in contact with the water.

Always disconnect the mains electricity supply whilst the equipment is being installed, repaired, 
maintained or handled. Consult a qualified electrician if in any doubt about wiring this product to  
the mains supply.

Your Midipond filter has been designed to 
need a minimum of maintenance.

When the filter system is first installed filter 
cleaning  may be increased for a period until 
the back log of accumulated pond waste is 
removed.

IMPORTANT:

 Please note all electrical work on garden lighting and power installations must 

comply with part P of the building regulations. Failure to comply is a criminal offense. If the 
installation of this product is not carried out by a competent electrician who is registered under 
the Part P self-certification scheme then you must notify the local building control department 
before work begins. For further information and guidance on this matter and other electrical 
installations in your home that might be covered by the relevant legislation, contact your local 
authorities building control department.

 ELECTRICAL INSTALLATION

MAINTENANCE & CLEANING

8

WARNING:

 

 

A Residual Current Device (RCD), also known as the Residual Current 

Circuit Breaker (RCCB), with a tripping current not exceeding 30mA must be installed 
in the supply circuit. A means of disconnection from the supply having a contact 
separation of at least 3mm in all  poles must be incorporated in the fixed wiring.

B

A

FILTER 
CLEANING

17.562 Blagdon_Midipond filter instructions_20000/28000 AW.indd   11

17/07/2017   16:35

Summary of Contents for Midipond 20000

Page 1: ...ww blagdonwatergardening co uk www interpetcentral com www pondaquariumproblemsolver co uk blagdon Midipond UV pond filter system 17 562 Blagdon_Midipond filter instructions_20000 28000 AW indd 2 17 0...

Page 2: ...nd Water Garden Filtration System Manufactured with advanced technology to create a clean and healthy pond for your fish IMPORTANT Please attach proof of purchase to this manual and file in a safe pla...

Page 3: ...sting the filter 6 Testing replacing the UVC lamp 7 Electrical installation 7 8 Maintenance 8 Dismantling the filter 8 Routine maintenance 9 How it works flow detail 9 Annual maintenance 10 Winter sto...

Page 4: ...t N A 16 Aeration Partition N A 17 UVC Lid N A 18 UVC feet hinge locating screws x8 N A 19 Filter lid N A 20 UVC electronics cap N A 21 18w 24w UVC lamp 18w 1050128 24w 1050111 22 UVC O ring gasket N...

Page 5: ...ltrs 2 310 gals 7 875 ltrs 1 732 gals 3 935 ltrs 870 gals Model Green water clarifier lamp wattage Max flow rate through UVC from pump Filter inlet hose from pump Filter outlet hose to pump MIDIPOND...

Page 6: ...E 1 metre 15cm UVC electronics access must not be below ground level WATERFALL ABOVE GROUND BELOW GROUND Filter Outlet Hose Installation PUMP FILTER above ground Filter outlet to Pond FOUNTAIN HOSE Fi...

Page 7: ...NTED HOSETAILS BLAGDON HOSE RECOMMENDED 40mm 32mm 25mm CUT Important The outlet hoses should be smooth bore pipe installed over as short a distance as possible with no kinks or bends The water level i...

Page 8: ...pump is to transfer dirty water from the pond to the Midipond filter Placing the pump at the opposite end of the pond to the filter will give the best results Foam free pump designs will give optimum...

Page 9: ...xposure to UVC light can damage your eyes or skin This unit is protected by a micro switch that prevents the UVC light from illuminating when the cover is removed even if the power is on In order to c...

Page 10: ...d IMPORTANT Please note all electrical work on garden lighting and power installations must comply with part P of the building regulations Failure to comply is a criminal offense If the installation o...

Page 11: ...ctively when partially blocked Foams may be cleaned vigorously under a running tap or hose Adding Blagdon Bio Start after filter maintenance will help replenish these beneficial bacterial populations...

Page 12: ...and codes descriptions on page 2 Annual Maintenance Check for wear Once a year you should dismantle your Midipond filter Dismantle the filter examining all the parts for wear or damage replacing any...

Page 13: ...o trap the fine waste Treat with Interpet Clear Pond treatment Do not clean the foams until the filter foam chamber starts to overflow into the carbon wool chamber The water is extremely dirty remove...

Page 14: ...check the filter selection chart The UVC quartz sleeve is dirty or coated in lime scale Gently remove the quartz sleeve and clean in Blagdon pond pump cleaner Follow all cloudy water trouble shooting...

Page 15: ...he Consumer Advice Line and follow any advice to correct the situation See details below Refunds can only be authorised by Interpet Blagdon CONSUMER ADVICE CONTACT DETAILS Interpet Blagdon Consumer Ad...