27
9. TROUBLESHOOTING
DC Status
Indicator
Flash Code
Fault
Description
Impact on
Controller
Notes
1 Battery
needs
recharging
Reduced drive is
available
The battery voltage has dropped
below 23.3 volts in neutral. Recharge
batteries.
2 Battery
voltage
too low
Drive Inhibited
The battery charge has dropped past
16.5 volts and is not sufficient to
allow safe driving.
3 Battery
voltage
too high
Drive inhibited.
If the scooter is
traveling, a soft
stop occurs.
The battery charge has exceeded 32
volts. Check the battery conditions
and the connections.
4 Current
limit
time out
Drive inhibited
The motor current has reached too
high a value. Check the condition of
the motor and loom(s).
Contact your service agent
5 Freewheel
engaged
Drive inhibited
Check brake connections. Check the
condition of the motor and the
loom(s).
Contact your service agent.
6 Speed
control
out of neutral
Drive inhibited
Return speed to neutral and reset
system. Readjust the speed lever
neutral if necessary.
7 Speed
control
fault
Drive inhibited
Check speed wiring for open or short
circuits. Check speed set-up.
Contact your service agent.
8
Motor fault
Drive inhibited
Contact your service agent
9 Internal
controller fault
Drive inhibited
Contact your service agent
Summary of Contents for DKS500 AMBASSADOR