14
PIC. 10
Drain Tap Sealed
OR
To close and seal push lever up Right or left
To open and drain pull lever down
Drain tap opened unsealed
CLEANING
ENSURE the infl ator is NOT running whilst cleaning. To keep
the infl ator clean, always wipe down after use. Wear eye
protection when cleaning. Only clean the infl ator with a
damp soft cloth. NEVER use liquid or solvents of any type.
Ensure ventilation slots are kept clean and free from dust/
dirt build up.
REPAIRS
Repairs to your infl ator should only be carried out by an
authorised service agent.
Call BLACKRIDGE for your closest centre, Aust.
Aust. 1300 660 457 N.Z. 0800 474 876.
TROUBLE SHOOTING
Infl ator will not start
Check that you have plugged the power lead into a standard 240V 10Amp
power point and turned the switch ON.
Check that you have turned the infl ator ON/OFF switch ON.
The air tank may be full. Use your air tool and the infl ator should start when
the pressure decreases to 85PSI.
Infl ator does not build up pressure
Check that the tank drain tap is sealed
Check that the air fi tting is not leaking. If leaking replace.
Infl ator smells like burnt oil
Using beyond the 50% duty cycle, allow to cool for 30 minutes before
reusing this infl ator.
IMPORTANT
NOTE
This infl ator has a maximum pressure of 8 bar.
Always regulate the air pressure to match your air
tool. Different air tools require different operating
pressures. Always check with the tool manufacturer
if unsure.
PIC. 9
Closed tap
Open tap
Rotate tap handle to open/close start/
stop the air supply to your attached
tool