background image

 

 

 

Sliding Vane Pumps: 5 to 2200 GPM 

Refined Fuels, Liquefied Gases, Solvents,Process

 

Stainless Steel Sliding Vane Pumps 

1 to 265 GPM:  Acids, Brines, Sugars, Syrups, 

Beer, Beet Juice, Cider, Flavor Extracts, etc. 

 

System One

®

 Centrifugal Pumps 

10 to 7500 GPM; Process, Marine 

 

Magnetic Drive Pumps 

Stainless Steel:  14 to 215 GPM 

 

HXL 6, 8 & 10” 

Sliding Vane Pumps 

 

130 to 2,220 GPM 

 

Refineries 

Terminals 

Barges 

Ships 

 

Reciprocating Gas Compressors 

Liquefied Gas Transfer, Boosting, Vapor Recovery 

 

Hand Operated Pumps 

Dispensing, Transfer, In-line 

   

 

Accessories 

Gear Reducers, Bypass Valves, Strainers

 

Visit  

www.blackmer.com

  for complete information on all Blackmer products 

 

 

 

 

 

 

 

1809 Century Avenue, Grand Rapids, Michigan 49503-1530 U.S.A. 

Telephone: (616) 241-1611  •  Fax: (616) 241-3752 

E-mail:  [email protected]    •    Internet Address:  www .blackmer.com 

Summary of Contents for SMVP15B

Page 1: ... one of the following signal words and be alert to the potential for personal injury death or major property damage Warns of hazards that WILL cause serious personal injury death or major property damage Warns of hazards that CAN cause serious personal injury death or major property damage Warns of hazards that CAN cause personal injury or property damage NOTICE Indicates special instructions whic...

Page 2: ... Disconnecting fluid or pressure containment components during pump operation can cause serious personal injury death or major property damage Do not operate without guards in place Operation without coupling guard can cause serious personal injury death or major property damage PUMP DATA PUMP IDENTIFICATION A pump Identification tag containing the pump serial number I D number and model designati...

Page 3: ...t be cleaned regularly to avoid pump starvation 5 Intake and discharge piping MUST be free of all leaks 6 Expansion joints placed at least 36 0 9m from the pump will compensate for expansion and contraction of the pipes Contact the flexible connector hose manufacturer for required maintenance care and design assistance in their use 7 Install vacuum and pressure gauges in the 1 4 NPT ports provided...

Page 4: ...h the value in the Table the bushing MUST be repositioned with a new Dim B Loosen the bolts and setscrew If Measurement A is High Move the bushing towards the motor C Face New Dim B table Dim B less the difference between Measurement A and table Dim A If Measurement A is Low Move the bushing away from the motor C Face New Dim B table Dim B plus the difference between Measurement A and table Dim A ...

Page 5: ...etting of the pump relief valve by gradually closing a valve in the discharge line momentarily and noting the reading on the pressure gauge This pressure reading should be 10 20 psi 96 1 4 bar higher than the maximum system operating pressure DO NOT run the pump for more than 15 seconds with the discharge valve completely closed If adjustments need to be made refer to Relief Valve Setting and Adju...

Page 6: ...st a closed discharge valve RELIEF VALVE SETTING AND ADJUSTMENT The factory relief valve pressure setting is marked on a metal tag attached to the valve body It is recommended the relief valve be set at least 10 20 psi 69 1 4 bar higher than the operating pressure or the system pressure control valve setting DO NOT remove the R V Cap OR adjust the relief valve pressure setting while the pump is in...

Page 7: ...o not operate without guard in place Operation without guards in place can cause serious personal injury major property damage or death Hazardous pressure can cause serious personal injury or property damage Disconnecting fluid or pressure containment components during pump operation can cause serious personal injury death or major property damage Strong magnetic field can cause personal injury Fa...

Page 8: ...ary DO NOT damage the containment can or pump head Remove and discard the containment can O ring 51 Strong magnetic field can cause personal injury Failure to use care when handling magnets can cause personal injury 6 With properly sized snap ring pliers remove the snap ring 83 from the shaft end Pull the inner magnet 52 from the shaft Remove the shaft key 35 7 Remove the four SMVP or eight MVP so...

Page 9: ...zed arbor press remove the old bearing from the head b To aid installation and prevent damage heat the head in an oven to 200 F 93 C c Coat the new bearing with a quality grade of bearing grease and place it on the inside face of the head with the notched end UP Align the notch in the bearing with the groove in the head d Using an arbor press CAREFULLY press the bearing into the head until it is f...

Page 10: ...n the inboard shaft end 2 Align the inner magnet 52 with the key and slide the magnet over the shaft with the pump end of the magnet towards the inboard head 3 Fully and squarely install the snap ring 83 into the groove in the end of the shaft 4 Check to ensure the pump shaft rotates freely when turned by hand 5 Install a new containment can O ring 51 into the groove provided on the hub of the inb...

Page 11: ...e incorrectly set 2 Leaks in suction piping 3 Incorrect rotation 4 Broken shaft 5 Pump vapor locked 6 Incorrect pump speed 7 Vanes damaged worn or incorrectly installed 8 Cavitation 9 Damaged or worn pump or system components 10 Excessive piping system friction losses 11 Relief valve incorrectly set worn or damaged 12 Operating against a closed discharge 13 Shaft bent or misaligned 14 Worn or dama...

Page 12: ... 215 GPM HXL 6 8 10 Sliding Vane Pumps 130 to 2 220 GPM Refineries Terminals Barges Ships Reciprocating Gas Compressors Liquefied Gas Transfer Boosting Vapor Recovery Hand Operated Pumps Dispensing Transfer In line Accessories Gear Reducers Bypass Valves Strainers Visit www blackmer com for complete information on all Blackmer products 1809 Century Avenue Grand Rapids Michigan 49503 1530 U S A Tel...