501-F00 Page 6/12
MAINTENANCE
Hazardous
machinery can
cause serious
personal injury.
FAILURE TO DISCONNNECT AND
LOCKOUT ELECTRICAL POWER OR
ENGINE DRIVE BEFORE ATTEMPTING
MAINTENANCE CAN CAUSE SEVERE
PERSONAL INJURY OR DEATH
Hazardous voltage.
Can shock, burn or
cause death.
FAILURE TO DISCONNECT AND
LOCKOUT ELECTRICAL POWER
BEFORE ATTEMPTING MAINTENANCE
CAN CAUSE SHOCK, BURNS OR
DEATH
Hazardous pressure
can cause serious
personal injury or
property damage
DISCONNECTING FLUID OR PRESSURE
CONTAINMENT COMPONENTS DURING
PUMP OPERATION CAN CAUSE
SERIOUS PERSONAL INJURY OR
PROPERTY DAMAGE.
Hazardous pressure
can cause serious
personal injury or
property damage
FAILURE TO RELIEVE SYSTEM
PRESSURE PRIOR TO PERFORMING
PUMP SERVICE CAN CAUSE SERIOUS
PERSONAL INJURY OR PROPERTY
DAMAGE.
SYSTEMS WITH METERS
WILL STILL BE PRESSURIZED EVEN
AFTER THE HOSE IS EMPTIED
Hazardous or toxic
fluids can cause
serious injury.
IF PUMPING HAZARDOUS OR TOXIC
FLUIDS, SYSTEM MUST BE FLUSHED
AND DECONTAMINATED, INSIDE AND
OUT, PRIOR TO PERFORMING SERVICE
OR MAINTENANCE
Do not operate
without guard
in place
OPERATION WITHOUT GUARDS IN
PLACE CAN CAUSE SERIOUS
PERSONAL INJURY, MAJOR
PROPERTY DAMAGE, OR DEATH.
NOTICE:
MAINTENANCE SHALL BE PERFORMED BY QUALIFIED TECHNICIANS ONLY. FOLLOWING THE APPROPRIATE
PROCEDURES AND WARNINGS AS PRESENTED IN THIS MANUAL.
SCHEDULED MAINTENANCE
STRAINERS
Strainers must be cleaned regularly to avoid pump starvation.
Schedule will depend upon the application and conditions.
LUBRICATION
NOTICE:
TO AVOID POSSIBLE ENTANGLEMENT IN MOVING
PARTS DO NOT LUBRICATE PUMP BEARINGS OR ANY
OTHER PARTS WHILE PUMP IS RUNNING
Pump bearings should be lubricated every one to twelve
weeks (AT MINIMUM), depending on the application, and
operating conditions.
Recommended Grease:
Exxon® - RONNEX MP Greas
e,
Mobil ® - MOBILITH AW-2 (64353-6) Grease,
or
equivalent.
Greasing Procedure:
1. Remove the grease relief fittings (76A) from the bearing
cover (27) and mounting bracket (108 or 108B).
2.
SLOWLY
apply grease with a hand gun until grease
begins to escape from the grease relief fitting port.
3. Replace the grease relief fittings (76A).
DO NOT overgrease pump bearings. While it is normal for
some grease to escape from the grease tell-tale hole after
lubrication, excessive grease on pumps equipped with
mechanical seals can cause seal failure.
Summary of Contents for LDF1A
Page 11: ...501 F00 Page 11 12 NOTES ...