background image

TA04702    A   Page 4 of 8   

CHARGING THE BATTERY

3.1

LED Lamp

Battery

Power Cord

Charger

1.

 

Connect the power cord to the Charger 144-CHR-LI and to an AC 
outlet. The LED Lamp blinks in Red [STAND BY]

NOTE:

 The rated input voltage for this unit is 100V-240V. Use of 

voltages over 260V will result in damage to the charger.

2. Insert the Battery firmly into the charger.

The LED Lamp lights in green [CHARGING].

NOTE:

 Do not short-circuit the Charger by placing foreign materials 

in the contacts on Charger, as this will damage the Charger.

3. Charging takes approximately 25 minutes (80% capacity) and         

45 minutes (100% capacity).
When charging is finished, the LED Lamp lights in orange 
[COMPLETION].

NOTE:

 If the LED Lamp displays solid red [HIGH TEMPERATURE], 

remove the Battery from the Charger and allow it to cool down 
before trying to charge it again.

4. When the battery will no longer charge or hold a charge, the LED 

Lamp blinks quickly in red [IMPOSSIBLE TO CHARGE].

5. When the charger is out of order, the LED Lamp does not light up 

even if AC power is supplied.

NOTE:

 Do not power the Charger with a portable generator.

ATTACHING & DETACHING THE BATTERY PACK

3.2

1. To attach the Battery, slide it into the base of the Tool 

until it stops and the Latches engage.

2. After inserting the Battery, check that it is securely in 

place by pulling it gently without pressing the Latches.

3. To detach the Battery, pull out the Battery while pressing 

the Latches.

Tool

Slide in

Pull Out

Battery

Latches
(both sides)

COMPRESSION CYCLES

3.3

This guide indicates the number of compression cycles that 
the TBM6PCR-LI can be expected to perform when the 
battery is fully charged. These figures are approximate and will 
vary according to the charging and other operating conditions, 
such as temperature, humidity, and battery condition.

CONDUCTOR

AVERAGE COMPRESSIONS

PER CHARGE

BAT-144-LI  

#6 Cu / Al

300

1/0 Cu /Al

220

4/0 Cu /Al

175

3.0

OPERATING INSTRUCTIONS

SWITCH OPERATIONS

3.4

1. The ram advances when the Trigger is depressed and 

stops when the Trigger is released.

2. To retract the ram, depress the Release Button. The ram 

continues to retract while the Release Button is 
depressed.

Trigger

Release Button

Summary of Contents for TBM6PCR-LI

Page 1: ...rying Case 3 3 0 Operating Instructions 4 3 1 Charging the Battery 4 3 2 Attaching Detaching the Battery 4 3 3 Compression Cycles 4 Page 3 4 Switch Operations 4 3 5 Compression Operation 5 3 6 Mainten...

Page 2: ...ls near energized conductors may lead to electrical shock causing severe injury or death DO NOT use these tools near energized conductors without adequately insulating operator and surroundings WARNIN...

Page 3: ...ging Strap LED Indicator Hanging Strap Advance Trigger Release Button Air Vent Contact Cover Air Vent Release Button Contacts BATTERY 144 BAT LI 2 2 CHARGER 144 CHR LI 2 3 LED Lamp Contacts Air Vent P...

Page 4: ...the LED Lamp does not light up even if AC power is supplied NOTE Do not power the Charger with a portable generator ATTACHING DETACHING THE BATTERY PACK 3 2 1 To attach the Battery slide it into the b...

Page 5: ...to ensure that the tool is kept in good working condition 2 To ensure smooth operation and prevent rust store the tool in a cool dry area Ensure that moving parts are lubricated regularly 3 When the p...

Page 6: ...nsure smooth operation Use the tool only after it has been at room temperature for 1 hour 5 Do not drop the tool Dropping the tool may damage the hydraulic circuit and cause malfunctions 6 Keep the he...

Page 7: ...TBM6PCR LI PARTS DIAGRAM 5 1 5 0 PARTS BREAKDOWN TA04702 A Page 7 of 8...

Page 8: ...2 16 Housing L 1 64 P 28 O Ring 300 21 1 17 Power Unit 558 12 1 65 P 28 Back Up Ring B C 55D 03 1 18 M4 X 14 Screw Ni ROB 128B 4 66 Ram RC58 01 1 19 Spring 598 R150 13 1 67 M4 X 5 Screw C P 55A 24 2...

Reviews: