background image

IMPORTANT:  Read

 

and understand all of the 

instructions and safety information in this manual 
before operating or servicing this tool. 

 

1.0

GENERAL INFORMATION

SAFETY RULES

1.1

1.

 BE FAMILIAR WITH YOUR TOOL.

Read the instruction manual. Become aware of its proper 
usage as well as the potential hazards.

2. 

KEEP WORK AREA CLEAN AND WELL LIGHTED.

Poor lighting and cluttered areas invite accidents.

3. 

USE SAFETY GLASSES.

4. 

MAINTAIN TOOL WITH CARE.

Keep tool in good condition at all times. Keep it clean for 
best and safest performance.

5. 

DON'T OVER-REACH.

Keep proper footing and balance at all times.

6. 

NEVER ATTEMPT TO MAKE A COMPRESSION ON A 
"HOT" LINE.

Never assume the power is OFF! Determine beforehand if 
any electrical hazards could exist when making a 
connection to a line or wire.

7. 

KEEP FINGERS AND OTHER BODY PARTS AWAY 
FROM COMPRESSION DIES & MOVING PARTS.

WARNING

Tools are 

NOT

 insulated for use on or near 

energized conductors. Use of these tools 
near energized conductors may lead to 
electrical shock, causing severe injury or 
death. 

DO NOT

 use these tools near 

energized conductors without adequately 
insulating operator and surroundings.

WARNING

Pinch point hazard. Compression Dies at high 
force can cause severe personal injury. Keep 
all body parts away from moving parts of the 
tool during operation.

FEATURES

1.2

• Fully automatic, self-contained power tool.
• Removable battery cartridge - simply change the 

cartridge for continuous use.

• One handed operation - control ram advancement 

and retraction with one hand.

• Protective rubber boot on Head.

SPECIFICATIONS

HYDRAULIC COMPRESSION TOOL:

TBM14CR-LI

Drive Unit: 

14.4V DC Motor

Dimensions:

 

19”L x 3.5”W x 10.5”H

Weight:

 

20 lbs. with battery

Capacities:

 

Cu #8-900 Kcmil

 

AL #10-750 Kcmil 

Output:

 

14 Tons

144-BAT-LI

BATTERY:

Battery Type: 

Sealed Lithium Ion

Voltage:

 

14.4V DC

Dimensions:

 

4.2”L x 3.3W x 2.6H

Capacities:

 

3.0Ah

Weight:

 

1.2 lbs.

Charging time:

  25 min. 80% Capacity

 

45 min. 100% Capacity

CHARGER:

144-CHR-LI

Input Voltage: 

120 - 240 V AC Single Phase

Dimensions:

  9”L x 5.7W x 3.2H

Weight:

 

3.5 lbs.

1.3

TA04724  B   Page 2 of 8

Summary of Contents for TBM14CR-LI

Page 1: ...r 3 2 5 Carrying Case 3 3 0 Operating Instructions 4 3 1 Charging the Battery 4 3 2 Attaching Detaching the Battery 4 Page 3 3 Compression Cycles 4 3 4 Switch Operations 4 3 5 Compression Operation 5...

Page 2: ...Use of these tools near energized conductors may lead to electrical shock causing severe injury or death DO NOT use these tools near energized conductors without adequately insulating operator and sur...

Page 3: ...Ring Strap Ring LED Indicator Advance Button Release Button Air Vent Contact Cover Air Vent Release Button Contacts BATTERY 144 BAT LI 2 2 CHARGER 144 CHR LI 2 3 LED Lamp Contacts Air Vent Power Cord...

Page 4: ...p even if AC power is supplied NOTE Do not power the Charger with a portable generator ATTACHING DETACHING THE BATTERY PACK 3 2 1 To attach the Battery slide it into the Battery Adapter at the rear of...

Page 5: ...it with a soft soaped cloth 4 Dust sand and dirt are a danger for any hydraulic device After each use the tool should be wiped with a clean cloth taking care to remove any residue especially close to...

Page 6: ...operation Use the tool only after it has been at room temperature for 1 hour 5 Do not drop the tool Dropping the tool may damage the hydraulic circuit and cause malfunctions 6 Keep the head and ram cl...

Page 7: ...TBM14CR LI PARTS DIAGRAM 5 1 5 0 PARTS BREAKDOWN TA04724 B Page 7 of 8...

Page 8: ...9 9 32 BALL 16 40 3 50 M10 X 12 SCREW F P 40 47 1 51 RELEASE PIN 351 12 1 52 P 3 O RING 16 36 1 53 VALVE CARTRIDGE R510 18 1 54 S 9 O RING 410 71 1 55 P 8 O RING B 700S 15 1 NO DESCRIPTION CODE QTY 56...

Reviews: