Black Box SW441A-R2 Manual Download Page 13

13

MATRIX SWITCH

4.  Operation

There is no power switch on the Matrix Switch. The unit is powered on as

long as the wallmount transformer is plugged into an active AC source.

When the unit is plugged in, a tone will sound for one second to signify a

successful reset. After this, the Matrix Switch will establish any connections

that were present when power was last lost. The indicator LEDs on the

front panel will light as appropriate.

The keypad is located on the top of the unit, with keys labeled 1-8 (or 1-4)

above a column of four LEDs. Each LED indicates a connection between

that input port (1-8 or 1-4) and a particular output port (A-D). When you

press a key, the appropriate LED indicator will advance through the

sequence A, B, C, D, and off (off indicating no connection to any outputs).

When you press a key, the LED will skip any output port that is already

connected to another input port. A connection to an output port must be

disconnected from its input before connecting with another input. When

all four output ports are connected to input ports, no other connection can

be made without first disconnecting an input from an output.

When you press a key, the Matrix Switch emits a short beep.
Under normal circumstances, the Matrix Switch unit should not need to

be reset. If you do need to reset the Switch, unplug the unit for two full

seconds, then plug it back in.

NOTE

The Matrix Switch will reestablish any connections that were present
when power was lost.

Summary of Contents for SW441A-R2

Page 1: ...1000 Park Drive Lawrence PA 15055 1018 724 746 5500 Fax 724 746 0746 Copyright 1998 Black Box Corporation All rights reserved...

Page 2: ...day 7 days a week Call 724 746 5500 or fax 724 746 0746 Mailing address Black Box Corporation 1000 Park Drive Lawrence PA 15055 1018 Web site www blackbox com E mail info blackbox com JANUARY 1998 SW...

Page 3: ...ommercial environment Operation of this equipment in a residential area is likely to cause interference in which case the user at his own expense will be required to take whatever measures may be nece...

Page 4: ...camente con carritos o pedestales que sean recomendados por el fabricante 7 El aparato el ctrico debe ser montado a la pared o al techo s lo como sea recomendado por el fabricante 8 Servicio El usuari...

Page 5: ...iado nicamente de acuerdo a las recomendaciones del fabricante 15 En caso de existir una antena externa deber ser localizada lejos de las lineas de energia 16 El cable de corriente deber ser desconect...

Page 6: ...K BOX and the Double Diamond logo are registered trademarks of BB Technologies Inc Centronics is a registered trademark of Centronics Corporation Any other trademarks mentioned in this manual are ackn...

Page 7: ...7 MATRIX SWITCH Contents 1 Specifications 8 2 Introduction 9 3 Installation 10 3 1 Parallel Installation 10 3 2 Serial Installation 11 4 Operation 13 Appendix Serial Pinouts 14...

Page 8: ...2 SW442AE R2 4 male input 4 female output SW443A R2 SW443AE R2 8 DB25 male input 4 DB25 female output SW444A R2 SW444AE R2 8 DB25 female input 4 DB25 male output Power A R2 models Input 115 VAC 60 Hz...

Page 9: ...umber SW441A R2 4 x 4 Matrix Switch Serial 230 VAC part number SW441AE R2 4 x 4 Matrix Switch Parallel 115 VAC part number SW442A R2 4 x 4 Matrix Switch Parallel 230 VAC part number SW442AE R2 4 x 8 M...

Page 10: ...the peripherals directly Centronics standard type cables are usually used when connecting computers to parallel printers The cable required is terminated on one end with a Centronics connector and on...

Page 11: ...ial or Parallel Application Use cable part number ECN25C M F for the serial input from the PC and the serial output to the modem Use cable part number BC00901 M F for the serial output to the printer...

Page 12: ...n applications that involve serial printers and modems connect straight through cables between the modems and the Matrix Switch and crossover cables between the printers and the Matrix Switch Use stra...

Page 13: ...ort A D When you press a key the appropriate LED indicator will advance through the sequence A B C D and off off indicating no connection to any outputs When you press a key the LED will skip any outp...

Page 14: ...TRIX SWITCH Appendix Serial Pinouts Table A 1 Serial Pinouts Input 1 8 Output A D In 2 Out Out 3 In In 4 Out Out 5 In Out 6 In Out 7 In Out 8 In Out 15 In Out 17 In In 19 Out In 20 Out Out 22 In Out 2...

Reviews: