PERFORMANCE SERVER CABINETS AND ACCESSORIES

6

3. Tool-Less Shelf (RM2010)

Figure 3-1. Tool-Less Shelf.

The Tool-Less Shelf for Performance Server Cabinets supports equipment weighing up to 150 lb. (68 kg). Its
support surface measures 17.3"W x 23.6"D (43.9 x 59.9 cm), and its rear mounting arms extend to give the shelf
a total front-rail-to-rear-rail depth of up to 35.5" (90.2 cm). It doesn’t require any additional equipment for
installation. To install the Tool-Less Shelf in a Performance Server Cabinet, take the following steps:

1. Make sure that all the shelf’s locking pins are retracted. Insert the shelf in the cabinet at an angle until the

mounting tabs have cleared the front rails.

Figure 3-2. Inserting the shelf in the cabinet.

Summary of Contents for RM2000A

Page 1: ...1000 Park Drive Lawrence PA 15055 1018 724 746 5500 Fax 724 746 0746 Copyright 2003 Black Box Corporation All rights reserved...

Page 2: ...46 5500 or fax 724 746 0746 Mailing address Black Box Corporation 1000 Park Drive Lawrence PA 15055 1018 Web site www blackbox com E mail info blackbox com CUSTOMER SUPPORT INFORMATION JUNE 2003 RM200...

Page 3: ......

Page 4: ...TRADEMARKS USED IN THIS MANUAL 1 TRADEMARKS USED IN THIS MANUAL Any trademarks mentioned in this manual are acknowledged to be the property of the trademark owners...

Page 5: ...er Cabinets RM2000A RM2080A 3 1 2 Tool Less Shelf RM2010 3 1 3 Fan Trays RM2011 and RM2012 3 2 Performance Server Cabinets 4 2 1 Introduction 4 2 2 Installation 4 3 Tool Less Shelf RM2010 6 4 440 CFM...

Page 6: ...M2070A RM2080A 35 5 90 2 cm Side Walls RM2000A RM2030A RM2050A RM2070A No RM2020A RM2040A RM2060A RM2080A Yes Weight RM2000A RM2050A 220 lb 99 8 kg RM2020A RM2060A 300 lb 136 1 kg RM2030A RM2070A 260...

Page 7: ...front and rear mesh doors Two models measure 78 7 H x 35 4 D 200 x 90 cm with sidewalls product code RM2020A or without RM2000A Two models measure 78 7 H x 39 4 D 200 x 100 cm with sidewalls product...

Page 8: ...c caps to protect them during the factory painting process To ground a device to one of these terminals remove the terminal s cap Run a ground wire with a ring lug from the device to the terminal Use...

Page 9: ...its rear mounting arms extend to give the shelf a total front rail to rear rail depth of up to 35 5 90 2 cm It doesn t require any additional equipment for installation To install the Tool Less Shelf...

Page 10: ...t enclosure Figure 3 3 Straightening the shelf to horizontal 3 Insert the shelf s front mounting tabs in the cabinet s front rails making sure that the shelf is level from side to side Figure 3 4 Fron...

Page 11: ...ng sure that the shelf is level from front to back Release all of its locking pins Figure 3 6 Inserting the shelf s rear mounting tabs This completes the installation Here s what the shelf should look...

Page 12: ...CHAPTER 3 Tool Less Shelf RM2010 9 Figure 3 8 Rear view of a completed installation...

Page 13: ...inside of the cabinet s rear door aligning the tray s mounting holes with an appropriate set of holes in the door s stiffener channel the flattened squared off tube that runs the height of the door on...

Page 14: ...top sides taking note of where the mounting screwholes at the ends of the tray are Position the tray so that the power cord is on the inside of the cabinet in this position the fans will blow hot air...

Page 15: ...ne halfway up along each side When you receive the cabinets from the factory these notches are sheathed with plastic caps Use a screwdriver or similar device to pry the caps off on the left side of on...

Page 16: ...CHAPTER 6 Interconnect Hardware RM2015 13 Figure 6 2 Using the Interconnect Hardware to join a pair of Performance Server Cabinets together Ovals show notch locations...

Page 17: ...PERFORMANCE SERVER CABINETS AND ACCESSORIES 14 7 Cage Nuts RM488 Use cage nuts and screws to rackmount standard devices such as hubs routers and switches...

Reviews: