Refer to Figure 1 in this chapter. Switch S1 is used to
reverse the TD, RD, and hardware flow control lines on
the EIA-232 interface. This eliminates the need to swap
these signals in your EIA-232 cables. If you connect the
SHM-B to your equipment using a “straight-through” or
“2:2” cable, then S1 must be set to the opposite of your
device’s configuration. For example, if your device is
configured as DTE, select DCE on S1. If you use a null
modem, “2:3”, or “3:2” cable to connect the SHM-B to
your equipment, then the setting for S1 will be identical
to your equipment’s setting. Refer to your equipment’s
manual for information concerning its DTE/DCE
setting. Table 2 gives the EIA-232 pinning of the SHM-B
with the DTE/DCE switch in the DCE position.