5.3 Troubleshooting
Here are some problems to look for:
•
Incompatible Baud Rates
.
Remember that both V.35
FOLDs and their attached V.35
devices must all have the same
baud rate. Any incompatibility
will result in corrupt data
transmission.
•
Incorrect V.35 Connections
. Use
a BERT (Bit Error Rate Tester)
to verify that your V.35 devices
and the V.35 ports of the FOLDs
are functioning properly.
•
Lead Mismatching
. The TX
connector of the local FOLD
should be attached to the RX
connector of the remote FOLD.
Conversely, the RX connector
of the local FOLD should be
attached to the TX connector
of the remote FOLD.
•
Maximum Link Distance
. Check
the specifications to make sure
that the fiberoptic cable you are
running between the two FOLDs
has not exceeded the operating
range.
•
Damaged Fiberoptic Cable
. If
one direction of the link fails the
TST test, try reversing the leads
on
both ends
of the link. Repeat
the TST test on both FOLDs. If
the other direction of the link
now fails the test, the problem
is in the fiberoptic cable.