![Black Box MDR3241A Manual Download Page 8](http://html.mh-extra.com/html/black-box/mdr3241a/mdr3241a_manual_2761384008.webp)
Manual Documentation Number: MDRxxxxA-807
13
Black Box Corporation - 1000 Park Drive - Lawrence, PA 15055-1018
www.blackbox.com -- Tech Support and Ordering: 724-746-5500 - Fax: 724-746-0746
F
NB v4.30*
0x23 (35d) Parity
0 – 5
Serial
Interfacing
1
0
PC v4.22*
0x1E (30d) Power-up
Mode
0 – 1
Command
Mode
Options
1
0
PK v4.30*
0x29 (41d) RF Packet
Size
0 -
0x100
[bytes]
Serial
Interfacing
2
0x40
(64d)
PW v4.22*
0x1D
(29d)
Pin Wake-up
0 – 1
Sleep (Low
Power)
1
0
RB v4.30*
0x20 (32d) Packetization
Threshold
0 -
0x100
[bytes]
Serial
Interfacing
2
0x01
RE
0x0E (14d) Restore
Defaults
-
(Special)
- -
RN v4.22*
0x19 (25d) Delay Slots
0 –
0xFF
[slots]
Networking
& Security
1
0
RO v4.2A*
0x21 (33d) Packetization
Timeout
0 –
0xFFF
F [x
200
µsec]
Serial
Interfacing
2
0
RP v4.2A*
0x22 (34d) RSSI PWM
Timer
0 -
0x7F
[x 100
msec]
Diagnostics
1
0
RR v4.22*
0x18 (24d) Retries
0 –
0xFF
Networking
& Security
1
0
RS v4.22*
0x1C
(28d)
RSSI
0x06 –
0x36
[read-
only]
Diagnostics
1
-
RT
0x16 (22d) DI2
Configuration
0 - 2
Serial
Interfacing
1
0
RZ v4.30*
0x2C
(44d)
DI Buffer
Size
[read-
only]
Diagnostics
- -
SB v4.2B*
0x36 (54d) Stop Bits
0 - 1
Serial
Interfacing
1
0
SH
v4.27C*
0x25 (37d) Serial
Number High
0 –
0xFFF
F
[read-
only]
Diagnostics
2
-
SL
v4.27C*
0x26 (38d) Serial
Number Low
0 –
0xFFF
F
[read-
only]
Diagnostics
2
-
SM
0x01 (1d)
Sleep Mode
0 – 8
Sleep (Low
Power)
1
0
ST
0x02 (2d)
Time before
Sleep
0x10 –
0xFFF
F [x
Sleep (Low
Power)
2
0x64
(100d)
14
Manual Documentation Number: MDRxxxxA-807
Black Box Corporation - 1000 Park Drive - Lawrence, PA 15055-1018
www.blackbox.com -- Tech Support and Ordering: 724-746-5500 - Fax: 724-746-0746
100
msec]
SY
0x17 (23d)
Time before
Initialization
0 –
0xFF
[x 100
msec]
Networking
& Security
1
0
(disabled
)
TO v4.30*
0x31 (49d)
DO2 Timeout
0 -
0xFFF
F (x 1
sec)
Serial
Interfacing
2
0x03
TR v4.22*
0x1B (27d)
Transmit
Error Count
0 –
0xFFF
F
Diagnostics
2
0
TT v4.22*
0x1A (26d)
Streaming
Limit
0 –
0xFFF
F [0 =
disabl
ed]
Networking
& Security
2
0xFFFF
VR
0x14 (20d)
Firmware
Version
0 x
0xFFF
F
[read-
only]
Diagnostics
2
-
WR
0x08 (8d)
Write
-
(Special)
- -
*Firmware version in which command and parameter options were first supported.
Zlinx Command Descriptions
Command descriptions in this section are listed alphabetically. Command categories
are designated within “< >” symbols that follow each command title. Zlinx Modules
expect parameter numerical values in hexadecimal (designated by the “0x” prefix).
AM (Auto-set MY) Command
<Networking & Security> AM
Command is used to
automatically set the MY
(Source Address) parameter from the factory-set module serial number. The address
is formed with bits 29, 28 and 13-0 of the serial number (in that order).
AT (Guard Time After)
Command
<Command Mode Options> AT
Command is used to set the DI
time-of-silence that follows the
AT command sequence
character (CC Command).
By default, AT Command Mode
will activate after one second of
silence.
NOTE: AT Commands issued without a parameter value will return the currently
stored parameter.
AT Command: ATAM
Binary Command: 0x3A (58 decimal)
Minimum firmware version required: 4.40
Binary Command: 0x05 (5 decimal)
Parameter
Range:
0x02 – 0xFFFF [x 100
milliseconds]
Number of bytes returned: 2
Default Parameter Value: 0x0A (10
decimal)
Related Commands: BT (Guard Time
Before), CC (Command Sequence
Character)