We strongly suggest you to repeat the steps 2 -3 times to make sure that
the bolts are tight
•
Repeat the steps 1 -6 on the remote end as well.
•
Now the system is secured with the fine adjustment bolts. The long term
alignment bolts should be tightened on side and on the bottom of the unit.
/Please note: During the tightening process should you experience some
movements . This should be compensated with further tightening of the fine
adjustment bolts/
8.5 Connecting to your Network
You have a TP head
You can find a TP connector unit in
your ODIU, with there connectors.
You have to plug in the TP cable of
your head into th e RJ45 connector.
Your network is connectable to the
LB system using the white one
rowed connector, where you have to
connect the four cable of your
network with the help of the punch
down tool. The order of the cable
can be seen on the figure.
The punch-down tool
Place your first cable on the top of the chosen
connector, without removing of the insulator from the
cable. Then using the punch down tool push down the
cable into the connector.