Page 33
724-746-5500 | blackbox.com
Chapter 4: Configuration
3. Repeat the above procedures to configure the remote IEEE 802.11b/g/n
Wireless Ethernet Extender.
4. Enter the actual distance in meters. For example, if the distance between the
two VAC bridges is 3 kilometers, enter 3000 in the field.
5. Use ping to check whether the link between the two bridges is OK.
6. To get better wireless connectivity, go to Status —> Connections. If the
connection is established, it will display association information for the remote
bridge, including MAC address, wireless mode, signal strength, and connection
time.
Figure 4-32. Antenna Alignment screen.
AP Repeater Mode
1. Choose Wireless > Basic Settings. Choose “AP Repeater” from Wireless Mode,
and click “Apply” to save it. You can also change the other parameters to
optimize your application before clicking “Apply.”