5
SDSL NETWORK EXTENDER SUBSCRIBER
1. Introduction
These instructions provide basic installation procedures for the SDSL Network
Extender Subscriber (LRA1200A-S).
CAUTION
We strongly recommend that you use proper static-protection
techniques when installing and handling this equipment.
NOTE
An SDSL Network Extender Subscriber must be connected (via the DSL
line) to an IP DSLAM Access Mux Module, such as the SDSL 12-Port
Access Mux 2000 Module (LRA1207C). Two subscriber units may not be
connected back-to-back.
2. Installation
Step #1: Unpacking the Unit
Unpack the Network Extender and power supply. If anything appears to be broken
or missing, contact Black Box immediately at 724-746-5500.
Step #2: Plug in the Power Supply
Plug the power supply into both the power source and the back of the unit. It does
not matter which order. Verify that the Power LED is lit.
Step #3: Plug in the DSL Connection
Plug in the DSL connection (see the bottom label for SDSL connection pinout
information).
NOTE
The length of the copper cable used between the local Network Extender
and the remote Network Extender will affect the linking of the DSL
connection. If the distance is greater than a particular speed will
support, the units will not link up. Also, it may take anywhere from one
to five minutes for the DSL connection to link up, depending on cable
quality and distance.