BLACK BOX

®

Quick Installation Guide

• LPH1000 Series Switches operate in harsh environments.
• Two power inputs connect simultaneously to live DC power sources.
• Alarm alerts you when power fails or a port disconnects.

Hardened Ethernet PoE Switch, (4) 10/100/1000 Mbps, (1) GE SFP

LPH1004A

Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500)

FREE technical support 24 hours a day, 7 days a week: Call 724-746-5500 or fax 724-746-0746

Mailing address: Black Box Corporation, 1000 Park Drive, Lawrence, PA 15055-1018

Web site: www.blackbox.com   •   E-mail: [email protected]

Customer 

Support 

Information

Summary of Contents for LPH1000 Series

Page 1: ...disconnects Hardened Ethernet PoE Switch 4 10 100 1000 Mbps 1 GE SFP LPH1004A Order toll free in the U S Call 877 877 BBOX outside U S call 724 746 5500 FREE technical support 24 hours a day 7 days a week Call 724 746 5500 or fax 724 746 0746 Mailing address Black Box Corporation 1000 Park Drive Lawrence PA 15055 1018 Web site www blackbox com E mail info blackbox com Customer Support Information ...

Page 2: ... user manual installation guide can be downloaded from the Black Box Web site or the FTP site To download from the Web site 1 Go to www blackbox com 2 Enter the LPH1004A in the search box 3 Click on the Resources tab on the product page and select the document you wish to download To download from the FTP site 1 Go to ftp blackbox com 2 Open the Manuals folder if using IE open the Anonymous folder...

Page 3: ...Spring DIN rail DIN rail clipper 1 35 3 5 cm 1 063 2 7 cm 0 295 0 75 cm Figure 1 DIN rail mounting Follow the steps below to mount the switch on the DIN Rail track 1 Insert the upper end of the DIN Rail clip into the back of the DIN Rail track from its upper side 2 Lightly push the bottom of the DIN Rail clip into the track 3 Check if the DIN Rail clip is tightly attached to the track 4 To remove ...

Page 4: ... V contacts on the terminal block connector 2 Tighten the wire clamp screws to prevent the DC wires from loosening Wire clamp screws V and V contacts Figure 2 Terminal block connector Wiring the Alarm Relay The switch provides one dry relay output for a power or port link event The alarm relay default is open and forms a closed circuit when the event occurs The relay conductor has a maximum of 24 ...

Page 5: ...ails or power fails Just change the DIP switch to the desired setting and the new configuration will be activated You don t need to reset the system On the bottom side of the switch there is one 6 pin DIP switch for alarm control Insert the power and port wiring and the DIP switch for the intended alarm is switched to ON The relay output will form a short circuit if the alarm occurred Figure 5 Set...

Page 6: ...elow for compatible SFPs Table 3 Compatible SFPs Part Number Description LFP411 SFP 1 25 Gbps Fiber with Extended Diagnostics 850 nm Multimode LC 300 m LFP412 SFP 1 25 Gbps Fiber with Extended Diagnostics 1310 nm Multimode LC 2 km LFP413 SFP 1 25 Gbps Fiber with Extended Diagnostics 1310 nm Single Mode LC 10 km LFP414 SFP 1 25 Gbps Fiber with Extended Diagnostics 1310 nm Single Mode LC 30 km LFP41...

Page 7: ...724 746 5500 blackbox com Page 7 NOTES ...

Page 8: ...ial or cost of cover damages resulting from any errors in the product information or specifications set forth in this document and Black Box Network Services may revise this document at any time without notice Copyright 2014 Black Box Corporation All rights reserved Black Box and the Double Diamond logo are registered trademarks of BB Technologies Inc Any third party trademarks appearing in this m...