The extended temperature capability of the DC-powered hardened LP004A’s can
go temperature uncontrolled environments, rated at –40`C to +75`C. If indoors, the DC
jack is also present and optionally can be used with an external AC power supply.
DC Power Terminals
: “+”, “-”, gnd
GND
: Terminal for “earth” or ground wire connection to the LP004A chassis
Input Voltage
: 36 – 60V DC (-48V DC)
Input current
: 0.2 amp max.(-48V
DC)
Power Consumption of the unit
:
3 watts typical, 4 watts max.