Transparent with Tagged Management
Transparent with Tagged Management mode passes both tagged and untagged traffic between
the DATA port and the OPTICS (or UPLINK) port. By using a VLAN Tag you can isolate
and route the management path in the module. This method can be used with or without
continuing the management path down the EXT MGMT port.
Configuring
To configure this mode, perform the following:
1.
Set the management DIP switch ON for the ports using management (in this example it is
the OPTICS (or UPLINK) 3 = ON and EXT MGMT 1 = ON).
2.
Set Transparent Mode to allow both tagged and untagged traffic to pass:
a.
From the Main Configuration Screen, press the space bar and type
config
. The
Configuration Screen displays:
b.
Enter
Y
in the Transparent Mode field and press any key (except S or Q) to open the
Transparent Mode Setup screen.
c.
Enter Y in the
Is a VLAN tag required on Management packets?
field. The screen displays the management tag fields:
Is a VLAN tag required on Management packets? [ Y ]
The Management Tag is [0 ]
Management Priority is [0 ]
d.
Enter the management tag (VLAN ID) and the priority (optional).
Is a VLAN tag required on Management packets? [ Y ]
The Management Tag is [7 ]
Management Priority is [0 ]
e.
Make sure the
Are VLAN Tags required on the EXT Port?
field is set to N.
TRANSPARENT MODE SETUP
Is a VLAN tag required on Management packets? [ Y ]
Do you want to enter the Extra Tag mode? Enter Y for Extra Tagging.
Enter N if you do not want Extra Tags [ N ]
Are VLAN Tags required on the EXT Port? [ N ]
Type S or F3 to save the new information
Type Q of F4 to quit and cancel changes
Reboot is required for any change to take affect.
Transparent Mode – with either (not both) Data and Optics Mgmt dipswitches
set to on, all traffic passes between Optics and Data port EXCEPT what has
been defined as the Management Domain. The Management Domain can either be
defined as untagged traffic or traffic with a specified VLAN ID.
In Transparent Mode with BOTH Optics and Data Mgmt dipswitches set to off,
all traffic passes between the Optics and Data Ports.
Default Mode – the unit passes only Untagged Packets.
The unit is currently
in Default Mode
.
Enter Y for Transparent Mode, N for no Transparent Mode or <enter> to
move to other options [ Y ]
13
When TX LinkLoss is enabled on the remote Managed Media Converter module, a twisted
pair fault turns off the fiber port transmitter. This allows the fiber-connected device to detect
a link fault.
TX LinkLoss
Cable fault with TX LinkLoss enabled on remote
X
X
X
X
X
X
X
X
CONNECTED
DEVICE
CONNECTED
DEVICE
HOST
REMOTE