Black Box LMC543C Manual Download Page 1

 

©

 

Copyright

 

2007.

 

Black

 

Box

 

Corporation.

 

All

 

rights

 

reserved

 

56

80011BB

01

 

A0

 

 

1000

 

Park

 

Drive

 

 

Lawrence,

 

PA

 

15055

1018

 

 

877

877

2269

 

 

Fax

 

724

746

0746

 

 
 
 
 
 
 
 
 
 
 
 
 

 

 

 

CUSTOMER 

SUPPORT 

INFORMATION 

Order 

toll-free

 in the U.S.: 

877-877-BBOX

 (outside U.S. call 

724-746-5500

FREE technical support, 24 hours a day, 7 days a week: Call 

724-746-5500

 or fax 

724-746-0746

 

Mail order:  

Black Box Corporation

, 1000 Park Drive, Lawrence, PA 15055-1018 

Web site: 

www.blackbox.com

   •   E-mail: 

[email protected]

 

DECEMBER 2007 

 LMC543C 

LMC544C 

 LMC546C 

LMC547C 

 LMC548C 

LMC549C 

 LMC550C 

LMC551C 

 LMC552C 

LMC553C 

 LMC554C 

LMC555C 

 LMC556C 

LMC557C 
LMC558C 

Managed 

Media Converter Module 10/100-II 

 

 

Summary of Contents for LMC543C

Page 1: ...tside U S call 724 746 5500 FREE technical support 24 hours a day 7 days a week Call 724 746 5500 or fax 724 746 0746 Mail order Black Box Corporation 1000 Park Drive Lawrence PA 15055 1018 Web site w...

Page 2: ...ception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one of the following measures Reorient or relocate the receiving antenn...

Page 3: ...nnection 2 Management Software 2 About Dynamic Host Control Protocol DHCP 3 About Features and Configuration 4 Hardware Configuration 4 Installation Instructions 6 Assigning IP Information 7 Software...

Page 4: ...0 km Requires SFP I55 Extended Diagnostic Module NOTE Single strand versions SS display the transmit frequency in the Media 2 column 53 Safety Certifications UL CUL Listed to Safety of Information Tec...

Page 5: ...g with EtherType TPID selection Remote monitoring and automatic alarms Bandwidth limiting The Host Remote pair configuration provides the following features Extends any 10 100 Mbps Ethernet based VLAN...

Page 6: ...t and is accessed by using the included RJ 45 to DB 9 adapter The serial connection provides access the Managed Media Converter module configuration screens these configuration screens are also access...

Page 7: ...nits in Host Remote applications and then reconfiguring all of the settings 3 iConfig Utility iConfig is a configuration utility in iView that lets you quickly and easily complete the first stages of...

Page 8: ...must be selected using DIP switches These feature selections include the following Enable Disable management on each port DIP switches 1 2 and 3 Configure the module to be either a Standalone a Host o...

Page 9: ...traffic passes between Optics and Data port EXCEPT what has been defined as the Management Domain The Management Domain can either be defined as untagged traffic or traffic with a specified VLAN ID I...

Page 10: ...ve screw The Managed Media Converter module includes on board SNMP logic When installed in an iMediaChassis manage the Managed Media Converter module from the chassis by using the Unified Management A...

Page 11: ...tall a 100 Mbps speed SFP Many SFPs including those from Black Box feature enhanced diagnostics capabilities with a Digital Diagnostics Monitoring Interface DDMI DDMI statistics provide real time acce...

Page 12: ...UPLINK port except for the device s management traffic When in Loopback mode the Managed Media Converter module stops the OPTICS or UPLINK port traffic from continuing on out of the DATA port Address...

Page 13: ...0 VLAN 32 0 0 VLAN 11 0 0 VLAN 22 0 0 Valid Vlan IDs are between 1 and 4094 Valid priorities are between 0 and 7 Type S or F3 to save the changes Type Q or F4 to quit and cancel changes Transparent Mo...

Page 14: ...lect the TPID for the Extra Tag 1 8100 2 9100 3 9200 Extra Tag TPID 1 8100 5 On the Host Managed Media Converter module enter Y in the Are Extra Tags left on the Data Port field to only accept the Ext...

Page 15: ...ort N Select the TPID for the Extra Tag 1 8100 2 9100 3 9200 Extra Tag TPID 1 8100 TRANSPARENT MODE SETUP Is a VLAN tag required on Management packets Y Do you want to enter the Extra Tag mode Enter Y...

Page 16: ...N ID 7 as management g Type reboot Now the Managed Media Converter is configured to pass all data between the OPTICS or UPLINK and DATA ports except that which is tagged with VLAN ID 7 All data tagged...

Page 17: ...Tag is 7 Management Priority is 0 e Make sure the Are VLAN Tags required on the EXT Port field is set to N TRANSPARENT MODE SETUP Is a VLAN tag required on Management packets Y Do you want to enter th...

Page 18: ...TE 39 Now the Managed Media Converter is configured to pass only tagged data between the OPTICS or UPLINK and DATA ports All untagged data is considered management traffic and passes from the OPTICS o...

Page 19: ...passes between Optics and Data port EXCEPT what has been defined as the Management Domain The Management Domain can either be defined as untagged traffic or traffic with a specified VLAN ID In Transpa...

Page 20: ...air 2 TX LinkLoss detects the fault and disables the OPTICS or UPLINK port 3 FX LinkLoss detects the fiber loss and disables the DATA port The link fault is passed through the media conversion and is...

Page 21: ...can also be performed using a Telnet session You can only use one Telnet session at a time There are three levels of Telnet account access User View status change own password and reboot Operator User...

Page 22: ...connected device Press Enter after each You can also assign a default gateway to allow the unit to be visible beyond the local network press Enter to skip When finished press Enter then type reboot f...

Page 23: ...e a new community string go to the main configuration screen and press C Enter the name of the new community up to 16 characters no spaces and press Enter Then type one of the following to assign the...

Page 24: ...you can launch a console session through the serial port and type in the command cleandb If both the serial and the iConfig passwords are forgotten you must contact technical support Ending Your Sess...

Page 25: ...two levels of cleandb The first level resets the Telnet iConfig password and all of the SNMP database values The second level additionally resets the IP address IP Subnet Gateway VLAN settings CLI com...

Page 26: ...FXLinkLoss Only Enabled TXLinkLoss Only Enabled FiberAlert Plus FXLinkLoss Enabled FiberAlert Plus TXLinkLoss Enabled TXLinkLoss Plus FXLinkLoss Enabled TXLinkLoss FXLinkLoss FiberAlert Enabled Fiber...

Page 27: ...trol Settings Unit FlowControl Disable FlowControl Globally Unit FiberAlert TXLinkLoss Plus FXLinkLoss Enabled Unit LoopBack No LoopBack Normal Traffic Mode Unit Max FrameSz Oversized Frames 1536 802...

Page 28: ...management isolation and is not recommended for normal use This section describes the telnet serial port screens and fields available for configuring the Managed Media Converter modes 29 In the above...

Page 29: ...0 0 VLAN 25 0 0 VLAN 4 0 0 VLAN 15 0 0 VLAN 26 0 0 VLAN 5 0 0 VLAN 16 0 0 VLAN 27 0 0 VLAN 6 0 0 VLAN 17 0 0 VLAN 28 0 0 VLAN 7 0 0 VLAN 18 0 0 VLAN 29 0 0 VLAN 8 0 0 VLAN 19 0 0 VLAN 30 0 0 VLAN 9 0...

Page 30: ...a Tagging Enter N if you do not want Extra Tags N Are VLAN Tags required on the EXT Port N Type S or F3 to save the new information Type Q of F4 to quit and cancel changes Reboot is required for any c...

Reviews: