Black Box LMC5118C Install Manual Download Page 2

or when 

Auto-Negotiation

is not preferred.  The fiber port does not auto-nego-

tiate; it is always 100 Mbps with Half- or Full-Duplex operation selectable
through the switch settings or 

iView

.

A

Au

utto

o--N

Ne

eg

go

ottiia

attiio

on

n

L2 10/100

ships from the factory with 

Auto-Negotiation

enabled on the twist-

ed pair port. In this mode, the twisted pair port negotiates for speed and duplex
(i.e. the module autosenses 10 Mbps Full-Duplex, 10 Mbps Half-Duplex, 100
Mbps Full-Duplex or 100 Mbps Half-Duplex with Flow Control).  

Configure 

Auto-Negotiation

on an 

L2 10/100 

by adjusting the DIP switch (for

unmanaged modules) or via the management software.  Please see 

Dip Switch

Locations

and 

Configuration Settings 

on page 2 of this manual. 

S

Se

elle

eccttiivve

e  A

Ad

dvve

errttiissiin

ng

g  W

Wiitth

h  A

Au

utto

o--N

Ne

eg

go

ottiia

attiio

on

n

Selective Advertising

, when used in combination with A

uto-Negotiation

, pro-

vides the added ability to selectively determine whether twisted pair Duplex
Modes and Speed are manually or automatically negotiated by the 

L2 10/100

.

If 

Selective Advertising

and 

Auto-Negotiation

are both enabled, then TX FDX

and TX 100 can be separately enabled (ON) and/or disabled (OFF.  

(See the 

Auto-Negotiation &Selective Advertising Configuration Chart

on page 2 for optional con-

figurations using these features.)

F

Fo

orrcciin

ng

g  tth

he

e  D

Du

up

plle

exx  M

Mo

od

de

e

The twisted pair and fiber ports on 

L2 10/100

modules can each be manu-

ally configured for either Half- or Full-Duplex operation. Before manually set-
ting the duplex mode, 

Auto-Negotiation

must be disabled. (Set Dip Switch 1 on

S1 to the OFF position.)

•   Configure the twisted pair port for Full-Duplex by setting Dip Switch 2 to the

OFF

position (Default). 

•   Configure the twisted pair port for Half-Duplex by setting Dip Switch 2 to the

ON

position.  

•   Configure the fiber port for Full-Duplex by setting  Dip Switch 6 to the 

OFF

position (Default).

•   Configure the fiber port for Half-Duplex by setting Dip Switch 6 to the 

ON

position.

F

Fo

orrcciin

ng

g  tth

he

e  S

Sp

pe

ee

ed

d  

The twisted pair port on 

L2 10/100

can also be manually set for 10 Mbps or

100 Mbps operation.  Before manually setting the speed,

Auto-Negotiation

must be disabled. (Set Dip Switch 1 on S1 to the OFF position.)

•   Configure the twisted pair port for 10 Mbps operation by setting Dip Switch 3

to the 

OFF

position.

•   Configure the twisted pair port for 100 Mbps operation by setting Dip Switch 3

to the 

ON

position.

NOTE:  The fiber port always operates at 100 Mbps.

IIn

nsstta

alllliin

ng

g  LL2

2  1

10

0//1

10

00

0  M

Mo

od

du

ulle

ess

L2 10/100

modules may be installed in any Black Box 

SNMP Manageable

Media Converter 

chassis.  Each module requires one slot in the chassis.  To

install a module, remove the blank brackets covering the slots where the mod-
ule is to be installed (if present) by removing the screws on the outside edges of
the bracket.  Slide the module into the chassis, via the card guides, until the
module is seated securely in the connector.  Secure the module to the chassis

4

5

by tightening the captive screw.  Save any “blanks” removed during installation
for future use should your configuration requirements change.

Installation Troubleshooting

During installation, first test your fiber and twisted pair connections with all
troubleshooting features disabled, then enable these features, if desired, just
before final installation.  This will reduce the features’ interference with testing.

•   When working with units where features cannot be disabled, you must estab-

lish BOTH your copper and fiber connections before the link LEDs will light!

•   To test a media converter by itself, first make sure you have an appropriate

fiber patch cable, then follow these steps to test:

S

Stte

ep

p  1

1::  

Connect the media converter to the twisted pair device with a 

twisted pair cable.

S

Stte

ep

p  2

2::

Loop a single strand of fiber from the transmit port to the receive

port of your media converter.

S

Stte

ep

p  3

3::

Verify that you have both twisted pair and fiber link on your media

converter.

•   Make sure that you are using the appropriate twisted pair cable. 
•   The fiber transmitters used on Black Box media conversion modules can over-

drive the receivers and cause data loss if used in installations where cable power
losses are low.  To verify this, measure the optical power at the receiver.  The
measured power should be no greater than specified and no less than the
Average Receive Sensitivity. If measured power is greater than specified, install
an optical attenuator to bring power within specification. Contact Black Box for
more information.

LLE

ED

D  O

Op

pe

erra

attiio

on

n

T

Tw

wiisstte

ed

d  P

Pa

aiirr  LLE

ED

Dss

T

TX

X  LLLL

Glows green when 

TX LinkLoss

is enabled.

1

10

00

0  

Glows yellow when 100 Mbps is selected on port.

LLN

NK

K//A

AC

CT

T

• Glows green when a link is established on port.
• Blinks green when data activity occurs.

F

FD

DX

X//C

CO

OLL

• Glows yellow when port is in 

Full-Duplex 

mode.

• Blinks yellow when port is operating in 

Half-Duplex

mode and collisions occur.

F

Fiib

be

err  O

Op

pttiicc  LLE

ED

Dss

F

FA

A**

Glows green when 

FiberAlert

is enabled.

* FiberAlert is not available/required on single-strand fiber L2 10/100 modules.

F

FX

X  LLLL

Glows green when 

FX LinkLoss

is enabled.

LLN

NK

K//A

AC

CT

T

• Glows green when a link is established on port.
• Blinks green when data activity occurs.

F

FD

DX

X//C

CO

OLL  

• Glows yellow when port is in Full-Duplex mode.
• Blinks yellow when port is operating in Half-Duplex 

mode and collisions occur.

Black Box Customer Service

Call: (724) 746-5500

Phone orders 24 hours a day,  7:00 AM Monday to

midnight Friday; 8:00 AM to 4:00 PM Saturday (EST)

Fax:   (724) 746-0746

or in North America 

1-800-321-0746

Mail order:

Black Box Corporation, 
1000 Park Drive, Lawrence, PA 15055-1018

Technical Support and fax orders 24 hours a day. 

S

Sp

pe

ecciiffiicca

attiio

on

nss

Environmental

Operating Temperature:  32° - 104° F (0° - 40° C)
Storage Temperature:  0° - 160° F (-20° - 70° C)
Humidity:  5 - 95% (non-condensing)

Power Consumption (Typical)

Input Load:  

5mA

W

Wa

arrrra

an

nttyy  IIn

nffo

orrm

ma

attiio

on

n

Please contact Black Box for complete warranty information.

F

Fiib

be

err  O

Op

pttiicc  C

Clle

ea

an

niin

ng

g  G

Gu

uiid

de

elliin

ne

ess

Fiber optic transmitters and receivers are extremely susceptible to contamination by particles of dirt or dust which can

obstruct the optic path and cause performance degradation.  Good system performance requires clean optics and connec-
tor ferrules.

1) Use fiber patch cords (or connectors, if you terminate your own fiber) only from a reputable supplier; low-quality

components can cause many hard-to-diagnose problems in an installation.

2) Dust caps are are installed by the manufactgurer to ensure factory-clean optical devices.  These protective caps

should not be removed until the moment of connecting the fiber cable to the device.  Assure that the fiber is prop-
erly terminated, polished and free of any dust or dirt and that the location is as free from dust and dirt as possible.

3) Store spare caps in a dust-free environment such as a sealed plastic bag or box so that, when reinstalled, they do

not introduce any contamination to the optics.

4) Should it be necessary to disconnect the fiber device, reinstall protective dustcaps.
5) If you suspect that the optics have been contaminated, alternate between blasting with clean, dry, compressed air

and flushing with methanol to remove dirt particles.

E

Elle

eccttrro

osstta

attiicc  D

Diisscch

ha

arrg

ge

e  P

Prre

ecca

au

uttiio

on

nss

Electrostatic discharge (ESD) can cause damage to your add-in modules. Always observe the following precautions

when installing or handling an add-in module or any board assembly.

1) Do not remove unit from its protective packaging until you’re ready to install it. 
2) Wear an ESD wrist grounding strap before handling any module or component. If you do not have a wrist strap,

maintain grounded contact with the system unit throughout any procedure requiring ESD protection.

3) Hold boards by the edges only; do not touch the electronic components or goldconnectors.
4) After removal, always place the boards on a grounded, static-free surface, ESD pad or in a proper ESD bag.  Do not

slide the board over any surface.

6

WARNING!

Integrated circuits and fiber optic components are extremely susceptible to electrostatic 

discharge damage.  Do not handle these components directly unless you are a qualified service 
technician and use tools and techniques that conform to accepted industry practices.

1000 Park Drive • Lawrence, PA  15055-1018 USA

TEL: (724) 746-5500 • FAX: (724) 873-7049

[email protected] • www.blackbox.com

© 2002 Black Box Corp.  All rights reserved.

The information in this document is subject to change without notice.  Black Box assumes no responsibility for any errors
that may appear in this document.  Product names are trademarks of the manufacturer.  Other brands or product names
may be trademarks and are the property of their respective companies.

Document Number 56-80911BB-00-A2

October 2002

L2 10/100 TX/SSFX Modules

must be used in pairs, with one module on one end of the conversion

and complementary module at the other, or with another Single-strand product from Black Box.

N O T E