LEH1000 Series Hardened Ethernet Switches Quick Start Guide

LEH1000 Series Switches Indicators.

LED

State

Indication

Power 1

Steady ON (Green)

Power ON

Off

Power OFF

Power 2

Steady ON (Green)

Power ON

Off

Power OFF

Power 3

Steady ON (Green)

Power ON

Off

Power OFF

10/100BASE-TX, 100BASE-FX/BX

LINK/ACT

Steady ON (Green)

A valid network connection is established

Flashing

Transmitting or receiving data. 

NOTE: ACT stands for activity.

100

Steady ON (Green)

Connection at 100-Mbps speed.

10/100/1000BASE-SX/LX/BX

LINK/ACT

Steady ON (Green)

A valid network connection is established

Flashing

Transmitting or receiving data. 

NOTE: ACT stands for activity.

1000

Steady ON (Green)

Connection at 1000-Mbps speed.

Power Input Assignment

Power 3

47–57 VDC

DC jack

Power 2

+

47–57 VDC

-

Power ground

Power 1

+

47–57 VDC

-

Power ground

Earth ground

Relay output rating

1 A @ 250 VAC

Relay Alarm Assignment

Fault

Warning signal disable for the following:
• The relay contact closes if Power 1 and Power 2 both fail, but Power 3 is ON. 
• The relay contact closes if Power 3 fails, but Power 1 and Power 2 are ON.

Summary of Contents for LEH1008A

Page 1: ...100BFX SFP DC power This quick start guide describes how to install and use the hardened Managed Ethernet Switch Designed for rugged environments Hardened Managed Ethernet Switches provide reliable sw...

Page 2: ...tches components Number in Figure 1 Product Name Description 1 Ports G1 and G2 LEH1008A 2GSFP 2 GE SFP ports LEH1008A 2SFP 2 SFP ports NOTE These connectors are not present on LEH1000A 2MMSC and LEH10...

Page 3: ...activity 100 Steady ON Green Connection at 100 Mbps speed 10 100 1000BASE SX LX BX LINK ACT Steady ON Green A valid network connection is established Flashing Transmitting or receiving data NOTE ACT s...

Page 4: ...ulation program such as HyperTerminal directly to the switch console port STEP 2 Configure the terminal emulation program settings When using the management method configure the terminal emulation pro...

Page 5: ...enable and press Enter to log on to Privileged Exec Mode or Enable Mode The switch_a prompt will show on the screen STEP 6 Log on to Configure Mode Configure Terminal Mode At the switch_a prompt type...

Page 6: ...LEH1000 Series Hardened Ethernet Switches Quick Start Guide Web Configuration STEP 1 Login to the switch Specify the default IP address 192 168 1 10 of the switch in the Web browser A login window wil...

Page 7: ...Hardened Ethernet Switches Quick Start Guide STEP 2 Log in using the factory default settings Enter the factory default login ID root Enter the factory default password no password Click on the Login...

Page 8: ...ch support available in 60 seconds or less Copyright 2014 Black Box Corporation All rights reserved Black Box and the Double Diamond logo are registered trademarks of BB Technologies Inc Any third par...

Reviews: