background image

100Mbps Intelligent “redundant twister” Modules:

LH7731A-RTX  RJ-45 to Redundant RJ-45 _______________ 100m/100m
LH7731A-RFXSC  RJ-45 to Redundant FX multimode SC ____ 100m/2km
LH7731A-RFXSCSM  RJ-45 to Redundant FX singlemode SC 100m/15km
LH7731A-RFXST  RJ-45 to Redundant FX multimode ST ____ 100m/2km

LH7731A-RFXSTSM  RJ-45 to Redundant FX singlemode ST _ 100m/15km

10Mbps Intelligent “redundant twister” Module:

LH7111A-TP  RJ-45 to Redundant RJ-45 ________________ 100m/100m

These modules incorporate three ports: a MAIN, a PRIMARY and a
SECONDARY port. Full redundant data paths are provided between the
PRIMARY and the SECONDARY ports.

LED Operation:

• PWR: normal operation
• SW: SECONDARY port active at some point; functions in

        Dynamic Recovery Mode only

• SECONDARY: port is active (PRIMARY is inactive)
• (MAIN) LK: valid link indication
• (MAIN) AT: receiving data
• (PRIMARY) LK: valid link indication
• (PRIMARY) AT: receiving data
• (SECONDARY) LK: valid link indication
• (SECONDARY) AT: receiving data

MDI-II to MDI-X Switch: MDI-II (default)
DIP Switch Settings:
• TX Switch UP: data from the MAIN port is transmitted simultaneously

on the PRIMARY and SECONDARY ports; data from the active port
(PRIMARY or SECONDARY) is transmitted on the MAIN port. NOTE:
the Link Switch must also be UP in order to send data out the inactive port.

• TX Switch DOWN (default): data from MAIN port is transmitted on

active port only.

• AUTO Switch UP: module automatically reverts back to the PRIMARY

port when the primary link is re-established.

• AUTO Switch DOWN (default): once the SECONDARY port has become

active, the module will not revert back to the PRIMARY port when the
primary link is re-established, unless the SECONDARY link is absent.

100Mpbs TX-to-FX Intelligent “twister” Modules:
LH7131A-SXSC RJ-45 to SX multimode SC _____________ 100m/300m
LH7131A-SXST RJ-45 to SX multimode ST _____________ 100m/300m
LH7131A-SC  RJ-45 to FX multimode SC ________________ 100m/2km
LH7131A-SMSC  RJ-45 to FX singlemode SC ____________ 100m/15km
LH7131A-ST  RJ-45 to FX multimode ST ________________ 100m/2km
LH7131A-SMST  RJ-45 to FX singlemode ST ____________ 100m/15km
LH7131A-PSC  RJ-45 to FX singlemode SC _____________ 100m/40km

These modules provide high-speed transparent integration of
100BASE-TX and 100BASE-FX segments.

LED Operation:

• PWR: normal operation
• LK: satisfactory receive link status on respective port
• AT: receiving data

MDI-II to MDI-X Switch: MDI-II (default)
Jumper Settings:
 A jumper switch configures the Link Loss Carry
Forward (LLCF) function.

• To enable LLCF: connect pins 1&2
• To disable LLCF: connect pins 2&3 (default)

100Mbps SM-to-MM Intelligent “twister” Modules:
LH7131A-SCSC  FX multimode SC to FX singlemode SC ___ 2km/15km
LH7131A-SCST  FX multimode SC to FX singlemode ST ___ 2km/15km
LH7131A-STSC  FX multimode ST to FX singlemode SC ___ 2km/15km
LH7131A-STST  FX multimode ST to FX singlemode ST ____ 2km/15km

These modules provide seamless integration between higher bandwidth
singlemode and multimode fiber optic segments.

LED Operation:

• PWR: normal operation
• LK: satisfactory link status on respective port
• AT: receiving data

Jumper Settings: A jumper switch configures the Link Loss Carry
Forward (LLCF) function.

• To enable LLCF: connect pins 1&2
• To disable LLCF: connect pins 2&3 (default)

10Mbps Thinnet Coaxial Intelligent “twister” Module:
LE7111A-BNC  RJ-45 to BNC ________________________ 100m/185m

This module provides twisted-pair to Thinnet coax segment integration.

LED Operation:

• PWR: normal operation
• LK: satisfactory receive link status on TP port
• AT: receiving data
• COL: detection of collision condition

MDI-II to MDI-X Switch: MDI-II (default)
Jumper Settings:
 A jumper is used to set either internal or external
termination of the BNC port.

• To enable internal 50

 termination: connect pins 1&2

• To enable use of external termination: connect pins 2&3 (default)

RJ-45

BNC

Jumper JP4 Termination

JP4

3

1

RJ-45

F/O ST/SMA/SC

LLCF

3   2   1

10Mbps F/O Intelligent “twister” Modules:
LE7111A-FSC  RJ-45 to FL multimode SC ________________ 100m/2km
LE7111A-FST  RJ-45 to FL multimode ST ________________ 100m/2km
LE7111A-SFST  RJ-45 to FL singlemode ST ______________ 100m/8km
LE7111A-FSMA  RJ-45 to FL multimode SMA ____________ 100m/2km

These modules provide transparent integration of 10BASE-T and
10BASE-FL segments.

LED Operation:

• PWR: normal operation
• LK: satisfactory receive link status on respective port
• AT: receiving data

MDI-II to MDI-X Switch: MDI-II (default)
Jumper Settings:
 A jumper switch configures the Link Loss Carry
Forward (LLCF) function.

• To enable LLCF: connect pins 1&2
• To disable LLCF: connect pins 2&3 (default)

RJ-45

DIP Switches

F/O SC (ST)

F/O SC (ST)

DIP Switches

RJ-45

RJ-45

RJ-45

1

2

3

4

5

RED

LLCF

LINK

AUTO

TX

1

2

3

4

5

RED

LLCF

LINK

AUTO

TX

RJ-45

F/O SC

RJ-45

F/O ST

LLCF

3
2
1

LLCF

3
2
1

F/O SC

F/O SC

F/O SC

F/O ST

LLCF

3
2
1

LLCF

3
2
1

• LINK Switch UP: module sends link on both the PRIMARY and SECOND-

ARY ports; the end station connected to the module sees a valid link state.

• LINK Switch DOWN (default): module sends link on the active port only;

the end station connected to the module sees a valid link state only if the
port on the module is active.

• LLCF Switch UP: Link Loss Carry Forward is enabled.

• LLCF Switch DOWN (default): Link Loss Carry Forward is disabled.

• RED Switch UP (default): redundancy is enabled; Operates in Dynamic

Recovery Mode (DRM).

• RED Switch DOWN: redundancy is disabled; Network Select Mode (NSM)

is enabled. NOTE: In this mode the reset push button toggles the active
port between A and B for each switch closure. The AUTO switch sets the
initial active port on power up: UP for SECONDARY; DOWN for
PRIMARY. The SW LED remains OFF in NSM.

DIP switches can be managed with console commands or with NetBeacon

Management Software. Refer to the Intelligent Media Converter

 Command

Line Interface Guide, or the NetBeacon

 Management Software

Installation & User Guide for software management information. For more
information on the Intelligent “redundant twister” modules, refer to the
Intelligent Media Converter “redundant twister”

 Installation & User

Guide.

LE7501A Management Module
Connected to the modules in the chassis via the backplane, this SNMP
agent reports individual board status to the network management software.

TP Data Rate: 10Mbps half-duplex; 20Mbps full-duplex
LED Operation:

• (TP) LK: link present
• (TP) AT: link present and packet received
• PWR: power supply present and ON
• (Console) A: power supply A present and ON
• (Console) B: power supply B present and ON
• (Console) R: system is operational
• (Console) ER: indicates system diagnostics or boot failure

PC Terminal Session Parameters:

9600 Baud / 8 data bit / 1 stop bit / No Parity / No Flow Control

Refer to the Intelligent Media Converter

 LE7500A Installation & User

Guide for information on booting the LE7501A Management Module. Refer
to the Intelligent Media Converter

 Command Line Interface Guide for

the software commands.

IMPORTANT: When setting DIP Switches: UP is furthest from the circuit board.

DOWN is closest to the circuit board.

NOTE:

 Link Loss Carry Forward (LLCF) functionality is incorporated on all intelligent twister modules with the exception of the LE7111A-BNC

module. Refer to the 

Intelligent Media Converter

 LE7500A Installation & User Guide

 for a complete description.

RJ-45

DB-9

JP2

JP3

JP1

MGT-10

LK

AT

C
O
N
S
O
L
E

T
P

PWR

A

B

R

ER