Installing the Intelligent Media Converter Modules

• The LE7501A Management Module can only be installed in the far

right-hand slot. See diagram.

• Intelligent “redundant twister”

 modules have DIP switches that must

be set prior to installation. Refer to the 

Intelligent Media Converter

“redundant twister” Module Installation & User Guide

 for more details.

• Intelligent “redundant twister” F/O modules require two slots.

• Modules must be firmly secured to the chassis before network

connections are made.

Follow the simple steps outlined below:

1. Grasp a module by the front panel as shown and insert into a slot

making sure that both the top and bottom of the card edges are lined

up with the top and bottom card guides.

2. Slide the module in until the top and bottom edges of the front panel

are flush and even with the top and bottom edges of the chassis and

secure to the chassis by turning the thumb screw clockwise until snug.

Specifications: 100Mbps Intelligent “twister” Modules
Data Rate

____________ 100Mbps half-duplex; 200Mbps full-duplex

Bit Delay

_________________________________________ < 40 bits

Twisted-Pair Interface
Connector

__________________________ Shielded RJ-45, 8-pin jack

Impedence

________________________________ 100 Ohms nominal

Signal Level Output (differential) ______________________ .95 to 1.05V
Signal Level Input _____________________________ 350mV minimum
Supported Link Length ____________________________________ 100m
Cable Type

___________________________________ Category 5 UTP

Multimode F/O Interface
Connector

________________________________________ ST or SC

RX Input Sensitivity _______________________ -31 dBm peak minimum
Output Power ___________________ -14 dBm to -23.5 dBm (50/125 

µ

m)

___________________ -14 dBm to -20 dBm (62.5/125 

µ

m)

Supported Link Length _______________________ up to 2km full duplex
Cable Type

____________________ 50/125, 62.5/125, 100/140 

µ

m F/O

Singlemode F/O Interface
Connector

________________________________________ ST or SC

RX Input Sensitivity _______________________ -31 dBm peak minimum
Output Power ______________________ -8 dBm to -15 dBm (9/125 

µ

m)

Supported Link Length ______________________ up to 15km full duplex
Cable Type

________________ 8.3/125, 8.7/125, 9/125, 10/125 

µ

m F/O

Singlemode F/O Interface — extended distance support
Connector

_____________________________________________ SC

RX Input Sensitivity ___________________________ -35 dBm minimum
Output Power ________________________ 0 dBm to -5 dBm (9/125 

µ

m)

Supported Link Length ______________________ up to 40km full duplex
Cable Type

________________ 8.3/125, 8.7/125, 9/125, 10/125 

µ

m F/O

10 BASE

LK

AT

LK

AT

PWR

R
X

TP

FL

T
X

10 BASE

LK

AT

LK

AT

PWR

R
X

TP

FL

T
X

DISCONNECT ALL POWER

SOURCES BEFORE SERVICING

AC IN

100-240V

50/60Hz

2A

DISCONNECT ALL POWER

SOURCES BEFORE SERVICING

AC IN

100-240V

50/60Hz

2A

MGT-10

LK

AT

C
O
N
S
O
L
E

T
P

PWR

A

B

R

ER

MGT-10

LK

AT

C
O
N
S
O
L
E

T
P

PWR

A

B

R

ER

10 BASE

LK

AT

COL

PWR

TP

BNC

10 BASE

LK

AT

COL

PWR

TP

BNC

10 BASE

LK

AT

LK

AT

PWR

R
X

TP

FL

T
X

10 BASE

LK

AT

LK

AT

PWR

R
X

TP

FL

T
X

100 BASE

LK

AT

LK

AT

PWR

R
X

T
X

R
X

M
M

S
M

T
X

100 BASE

LK

AT

LK

AT

PWR

R
X

S
M

T
X

R
X

T
X

M
M

100 BASE

LK

AT

LK

AT

PWR

R
X

T
X

M
M

R
X

T
X

S
M

100 BASE

LK

AT

LK

AT

PWR

R
X

S
M

T
X

R
X

M
M

T
X

100 BASE

LK

AT

LK

AT

PWR

R
X

S
M

T
X

R
X

T
X

M
M

100 BASE

LK

AT

LK

AT

PWR

R
X

S
M

T
X

R
X

M
M

T
X

100 BASE

LK

AT

LK

AT

PWR

R
X

TX

FX

T
X

100 BASE

LK

AT

LK

AT

PWR

R
X

TX

FX

T
X

100 BASE

LK

AT

LK

AT

PWR

R
X

TX

FX

T
X

100 BASE

LK

AT

LK

AT

PWR

R
X

TX

FX

T
X

100 BASE

LK

AT

LK

AT

PWR

R
X

TX

FX

T
X

100 BASE

LK

AT

LK

AT

PWR

R
X

TX

FX

T
X

100 BASE

“redundant twister”

MAIN

RESET

LK

AT

PRIMARY

LK

AT

SECONDARY

LK

AT

R
X

T
X

R
X

T
X

PWR

SW

100 BASE

“redundant twister”

MAIN

RESET

LK

AT

PRIMARY

LK

AT

SECONDARY

LK

AT

R
X

T
X

R
X

T
X

PWR

SW

100 BASE

“redundant twister”

MAIN

RESET

LK

AT

PRIMARY

LK

AT

SECONDARY

LK

AT

R
X

T
X

R
X

T
X

PWR

SW

100 BASE

“redundant twister”

MAIN

RESET

LK

AT

PRIMARY

LK

AT

SECONDARY

LK

AT

R
X

T
X

R
X

T
X

PWR

SW

100 BASE

M
A
I
N

P
R
I

S
E
C

RESET

LK

AT

LK

AT

LK

AT

SEC

PWR

SW

Intelligent Media Converter™ 7500

Intelligent Media Converter™ 7500

Specifications: 10Mbps Intelligent “twister” Modules
Data Rate

______________ 10Mbps half-duplex; 20Mbps full-duplex

Bit Delay

__________________________________________ < 5 bits

Twisted-Pair Interface
Connector

__________________________ Shielded RJ-45, 8-pin jack

Impedence

________________________________ 100 Ohms nominal

Signal Level Output __________________________________ 2.0 to 2.8V
Signal Level Input _____________________________ 350mV minimum
Supported Link Length ____________________________________ 100m
Cable Type

_____________________________ Category 3, 4 or 5 UTP

Multimode F/O Interface
Connector

______________________________________ ST or SMA

RX Input Sensitivity ___________ 10BASE-FL -32.5 dBm peak minimum
Output Power _________________ -21.8 dBm to -16.8 dBm (50/125 

µ

m)

___________________ -19 dBm to -14 dBm (62.5/125 

µ

m)

Supported Link Length _______________________ up to 2km full duplex
Cable Type

____________________ 50/125, 62.4/125, 100/140 

µ

m F/O

Singlemode F/O Interface
Connector

_____________________________________________ ST

RX Input Sensitivity ___________ 10BASE-FL -32.5 dBm peak minimum
Output Power _____________________ -17 dBm to -23 dBm (9/125 

µ

m)

Supported Link Length _______________________ up to 8km full duplex
Cable Type

________________ 8.3/125, 8.7/125, 9/125, 10/125 

µ

m F/O

Thinnet Coax Interface
Connector

___________________________________ BNC receptacle

Internal Transceiver _________________________________ IEEE 802.3
Termination

_____________________________ User Selectable Jumper

Supported Link Length ________________________________ up to 185m
Cable Type

_______________________________ RG-58 coaxial cable

10 BASE

LK

AT

LK

AT

PWR

R
X

TP

FL

T
X

MGT-10

LK

AT

C
O
N
S
O
L
E

T
P

PWR

A

B

R

ER

10 BASE

LK

AT

COL

PWR

TP

BNC

10 BASE

LK

AT

LK

AT

PWR

R
X

TP

FL

T
X

10 BASE

LK

AT

LK

AT

PWR

R
X

TP

FL

T
X

100 BASE

LK

AT

LK

AT

PWR

R
X

T
X

R
X

M
M

S
M

T
X

100 BASE

LK

AT

LK

AT

PWR

R
X

T
X

M
M

R
X

T
X

S
M

100 BASE

LK

AT

LK

AT

PWR

R
X

S
M

T
X

R
X

T
X

M
M

100 BASE

LK

AT

LK

AT

PWR

R
X

S
M

T
X

R
X

M
M

T
X

100 BASE

LK

AT

LK

AT

PWR

R
X

TX

FX

T
X

100 BASE

LK

AT

LK

AT

PWR

R
X

TX

FX

T
X

100 BASE

LK

AT

LK

AT

PWR

R
X

TX

FX

T
X

100 BASE

LK

AT

LK

AT

PWR

R
X

TX

FX

T
X

100 BASE

“redundant twister”

MAIN

RESET

LK

AT

PRIMARY

LK

AT

SECONDARY

LK

AT

R
X

T
X

R
X

T
X

PWR

SW

100 BASE

“redundant twister”

MAIN

RESET

LK

AT

PRIMARY

LK

AT

SECONDARY

LK

AT

R
X

T
X

R
X

T
X

PWR

SW

10 BASE

LK

AT

LK

AT

PWR

R
X

TP

FL

T
X

DISCONNECT ALL POWER

SOURCES BEFORE SERVICING

AC IN

100-240V

50/60Hz

2A

DISCONNECT ALL POWER

SOURCES BEFORE SERVICING

AC IN

100-240V

50/60Hz

2A

MGT-10

LK

AT

C
O
N
S
O
L
E

T
P

PWR

A

B

R

ER

10 BASE

LK

AT

COL

PWR

TP

BNC

100 BASE

LK

AT

LK

AT

PWR

R
X

S
M

T
X

R
X

T
X

M
M

100 BASE

LK

AT

LK

AT

PWR

R
X

S
M

T
X

R
X

M
M

T
X

100 BASE

LK

AT

LK

AT

PWR

R
X

TX

FX

T
X

100 BASE

LK

AT

LK

AT

PWR

R
X

TX

FX

T
X

100 BASE

“redundant twister”

MAIN

RESET

LK

AT

PRIMARY

LK

AT

SECONDARY

LK

AT

R
X

T
X

R
X

T
X

PWR

SW

100 BASE

“redundant twister”

MAIN

RESET

LK

AT

PRIMARY

LK

AT

SECONDARY

LK

AT

R
X

T
X

R
X

T
X

PWR

SW

100 BASE

M
A
I
N

P
R
I

S
E
C

RESET

LK

AT

LK

AT

LK

AT

SEC

PWR

SW

Card Guide

Blank Panel

Card Guide

Slot for Management Module

Slot for Management Module

Thumb Screw

100 BASE

“redundant twister”

MAIN

RESET

LK

AT

PRIMARY

LK

AT

SECONDARY

LK

AT

R
X

T
X

R
X

T
X

PWR

SW

IMPORTANT!

Tighten thumb screw

to secure each module firmly

to chassis before making

network connections.

Intelligent Media Converter™ 7500

Intelligent Media Converter™ 7500

Installation & User Guide

5660-750002-002 A

8/99

JULY 1999

LE7500A-12

LE7500A-12P

LE7500A-16
LE7500A-17

© Copyright 1999. Black Box Corporation. All rights reserved.

1000 Park Drive • Lawrence, PA 15055-1018 • 724-746-5500 • Fax 724-746-0746

Any trademarks or trade names that appear in this document are

the property of their respective owners.

The information contained in this document is assumed to be correct and

current. The manufacturer is not responsible for errors or omissions and

reserves the right to change specifications at any time without notice.

CUSTOMER SUPPORT INFORMATION
Order toll-free in the U.S. 24 hours, 7 A.M. Monday to midnight Friday: 877-877-BBOX
FREE technical support, 24 hours a day, 7 days a week: 724-746-5500 (fax 724-746-0746)
Mail order:  Black Box Corporation, 1000 Park Drive, Lawrence, PA 15055-1018
Web site: www.blackbox.com   •   E-mail: [email protected]

Reviews: