background image

STRAP

IDENTITY

FUNCTION

POSSIBLE SETTINGS

FACTORY

SETTINGS

Data Rate

(Kbps)

0 = 19.2 Kbps
1 = 14.4 Kbps
2 = 9.6 Kbps
3 = 7.2 Kbps
4 = 4.8 Kbps
5 = 3.6 Kbps
6 = 2.4 Kbps
7 = 1.2 Kbps

Determines the data rate.

2 = 9.6 Kbps

INT
EXT
RCV
ASY

XMT TIMING

Determines whether the transmit-timing signal
comes from the internal clock, external clock, or
receive clock, or whether the unit operates in async.

INT (Internal Clock)

2W
4W

2W/4W

Determines whether the unit uses 2 wires or 4
wires.

4W (4 wires)

0 ms
8 ms
64 ms

CTS DELAY

Determines the RTS-to-CTS delay

8 ms

Determines the transmit carrier mode.
ON: Transmit carrier is constantly ON.
CTRL:  Transmit carrier is ON only when RTS is
            high.
            CTRL should be used in multipoint
            applications.

ON
CTRL

ON

CARRIER

0 dBm
-3 dBm
-6 dBm
-9 dBm

Determines transmit-output level to the line.

XMT LEVEL

0 dBm

600
300
150
LOW

150 [ohms]

Determines transmit-line impedance.
     For Multi-point applicatoins, set the master
    modem to
     LOW

XMT

IMPEDANCE

RCV

IMPEDANCE

Determines receive-line impedance.
     For Multi-point applications, set the master
    modem and the last modem in line 10 150; set all
    others to HIGH.

150
300
600
HIGH

150 [ohms]

EN
DIS

EN

PIN 18

Enables/Disables Analog loopback command from
the DTE on Pin 18

PIN 21

Enables/Disables Remote loopback command from
the DTE on Pin 21.

RLB EN
RLB DIS

RLB EN

STRAP

IDENTITY

FUNCTION

POSSIBLE SETTINGS

FACTORY

SETTINGS

SWITCH

Enables/Disables control of the DIG, ANA, and REM
loopbacks with the front-panel pushbuttons.

EN
DIS

EN

GND

Connect:  Connects Signal Ground to Chassis
                Ground.
DIS:  Isolates grounds from each other.

CONNECT
DIS CONN

CONNECT

AGC

ON:  AGC always ON.
CTRL:  AGC ON if DCD is ON, remains at last level
            of amplification if DCD goes OFF.

ON
CTRL

ON

V.54 Delay

ON:  Activates V.54 delay, preventing multiple
loopback of tail-end circuits.
OFF:  No delay

ON
OFF

OFF

S3 and S4 determine character lengths when unit is
in async mode.

 S3

 S4

BITS

OFF

OFF

   8

OFF

 ON

   9

ON

OFF

  10

ON

 ON

  11

10 Bits

S2 determines amount of stop-bit shortening for
async mode.

ON = 25%
OFF = 12.5%

12.5%

S1 is not used.

ASYNC

LENGTH

Reviews: