Express Ethernet Switch LB8415A-US
9
Installation
Selecting a Site for the Switch
As with any electronic device, you should place the switch where it will not be subject
to extreme temperatures, humidity, or electromagnetic interference. Specifically, the
site you select should meet the following requirements:
•
The ambient temperature should be between 32 and 104 degrees Fahrenheit (0 to
40 degrees Celsius).
•
The relative humidity should be less than 90 percent, non-condensing.
•
Surrounding electrical devices should not exceed the electromagnetic field (RFC)
standards for IEC 801-3, Level 2 (3V/M) field strength.
•
Make sure that the switch receives adequate ventilation. Do not block the
ventilation holes on the side of the switch or the fan exhaust port on the rear of the
switch.
•
The power outlet should be within 1.8meter (6 feet) of the switch.
Connecting to Your Network
Connect network cables from computers or network segments to the TX ports on the
back panel.
Table 2: Cabling Information
Speed Connector
Port
Speed
Half/Full Duplex
Cable
100BaseTX
RJ-45
100/200 Mbps
100 m, Category 5 STP/UTP
10BaseT
RJ-45
10/20 Mbps
100 m, Category 3, 4, or 5 STP/UTP
100BaseFX
Multi-mode
SC, ST, MT-RJ,
VF-45, or LC
100/200 Mbps
Up to 2km, 50 or 62.5/125µm
Multi-mode fiber cable
100BaseFX
Single-mode
SC
100/200 Mbps
Up to 75km, 9 or 10/125µm
Single-mode fiber cable