16
RS-232/485 CONVERTER
3.1.1 DIP S
WITCH
S1 S
ETTINGS
DIP switch S1 is used to configure receive impedance
(termination), 2-wire/4-wire operation and “echo”
enable/disable.
Table 3-1
shows the factory-default
settings for switch S1. Following
Table 3-1
is a
detailed description of each switch.
Table 3-1. Switch S1 Summary Table (factory defaults in bold)
Position
Function
OFF Position
ON Position
S1-1
RCV impedance (termination)
16 K ohms, typ.
120 ohms
S1-2*
2-wire/4-wire
4-wire
2-wire
S1-3*
2-wire/4-wire
4-wire
2-wire
S1-4
Echo Mode
Echo OFF
Echo ON
*Switches S1-2 and S1-3 should be switched simultaneously.