Black Box HS100A Manual Download Page 5

4

MULTI-PURPOSE AMPLIFIER AND TWO-PRONG CARBON AMPLIFIER

CAUTION:

Users should not attempt to make such connections themselves, but should contact the appropriate electric inspection authority,
or electrician, as appropriate.

The LOAD NUMBER (LN) assigned to each terminal device denotes the percentage of the total load to be
connected to a telephone loop which is used by the device, to prevent overloading. The termination on a
loop may consist of any combination of devices, subject only to the requirement that the total of the load
numbers of all the devices does not exceed 100.

NORMAS OFICIALES MEXICANAS (NOM) ELECTRICAL SAFETY STATEMENT

INSTRUCCIONES DE SEGURIDAD

1. Todas las instrucciones de seguridad y operación deberán ser leídas antes de que el aparato eléctrico

sea operado.

2. Las instrucciones de seguridad y operación deberán ser guardadas para referencia futura.

3. Todas las advertencias en el aparato eléctrico y en sus instrucciones de operación deben ser respetadas.

4. Todas las instrucciones de operación y uso deben ser seguidas.

5. El aparato eléctrico no deberá ser usado cerca del agua—por ejemplo, cerca de la tina de baño, lavabo,

sótano mojado o cerca de una alberca, etc..

6. El aparato eléctrico debe ser usado únicamente con carritos o pedestales que sean recomendados por

el fabricante. 

Summary of Contents for HS100A

Page 1: ...Multi Purpose Amplifier HS100A Two Prong Carbon Amplifier HS101A...

Page 2: ...operated in a commercial environment Operation of this equipment in a residential area is likely to cause interference in which case the user at his own expense will be required to take whatever meas...

Page 3: ...done the telephone company may temporarily disconnect service 3 If you have problems with your telephone equipment after installing this device disconnect this device from the line to see if it is ca...

Page 4: ...ser s satisfaction Before installing this equipment users should ensure that it is permissible to be connected to the facilities of the local telecommunications company The equipment must also be inst...

Page 5: ...devices does not exceed 100 NORMAS OFICIALES MEXICANAS NOM ELECTRICAL SAFETY STATEMENT INSTRUCCIONES DE SEGURIDAD 1 Todas las instrucciones de seguridad y operaci n deber n ser le das antes de que el...

Page 6: ...lor como radiadores registros de calor estufas u otros aparatos incluyendo amplificadores que producen calor 11 El aparato el ctrico deber ser connectado a una fuente de poder s lo del tipo descrito e...

Page 7: ...ntilaci n 18 Servicio por personal calificado deber ser provisto cuando A El cable de poder o el contacto ha sido da ado u B Objectos han ca do o l quido ha sido derramado dentro del aparato o C El ap...

Page 8: ...d trademark of Black Box Corporation Northern Telecom is a registered trademark of Nortel Networks Panasonic is a registered trademark of Matsushita Electric Industrial Co Ltd Toshiba is a registered...

Page 9: ...plifier 11 3 How to Make a Call 12 3 1 Multi Purpose Amplifier 12 3 2 Two Prong Amplifier 12 4 Telephone Compatibility and Setup 14 4 1 Setup Process 1 16 4 2 Setup Process 2 17 Setup Process 2a 18 5...

Page 10: ...are available Multi Purpose Amplifier Two Prong Carbon Amplifier The Multi Purpose Amplifier works with phones that have modular handset connectors The Two Prong Carbon Amplifier works with phones th...

Page 11: ...dset cord 2 Headset cord 3 Short telephone cord 4 Quick Disconnect 5 Headset stand NOTE The Multi Purpose Amplifier works with phones that have modular handset connectors The Two Prong Carbon Amplifie...

Page 12: ...e 2 2 1 Two Prong Amplifier 2 Headset cord 3 Quick Disconnect 4 Telephone NOTE The Multi Purpose Amplifier works with phones that have modular handset connectors The Two Prong Carbon Amplifier works w...

Page 13: ...s a volume control setting please set it to the mid to low end of the range for the best performance Figure 3 3 Volume Control on the Multi Purpose Amplifier 3 2 Two Prong Amplifier The Two Prong Ampl...

Page 14: ...TER 3 How to Make a Call Figure 3 4 Volume Control on the Two Prong Amplifier NOTE If you re using the adapter in the battery mode low batteries are indicated by a beeping noise in the headset Volume...

Page 15: ...facturer Telephone System Station Telephone Model Telephone Type Switch Transmit Control Require Batteries AT T System 75 85 7100 7300 and A 1 10 NO G1 G2 G3 7400 Series AT T Merlin BTN BIS and 7000 S...

Page 16: ...nsumer Products FeaturePhone 400 1300 and 1600 Series Comdial Executech 3500 and 6000 Series Mitel SX 100 200 and 2000 Superset 3 4 and 7 NEC Electra DTerm 4 and 5 Northern Telecom Unity All Sets E 1...

Page 17: ...e type switch according to Table 4 1 Figure 4 2 Adjusting the Telephone Type Switch 3 If batteries are required according to Table 4 1 insert two AA batteries as indicated on the bottom of the battery...

Page 18: ...C Figure 4 7 Adjusting the Telephone Type Switch to Position C 3 Take the phone off the hook and make a call If you do not get a dial tone go to setup process 2a on the next page If you achieve a conn...

Page 19: ...ng the Batteries 3 Make a call and adjust the transmit control to a satisfactory level If you still do not hear a dial tone recheck connections and try the setup again Figure 4 11 Adjusting the Transm...

Page 20: ...is in use to indicate to co workers that you are on the telephone You can adjust it so the light can be seen from the direction you prefer Figure 5 1 On line Indicator 5 2 AC Power Adapter Remove the...

Page 21: ...efficient and accurate assistance if you have a complete description including the nature and duration of the problem when the problem occurs the components involved in the problem any particular app...

Page 22: ...EE technical support 24 hours a day 7 days a week Call 724 746 5500 or fax 724 746 0746 Mailing address Black Box Corporation 1000 Park Drive Lawrence PA 15055 1018 Web site www blackbox com E mail in...

Reviews: