Installation steps:
•
Short the jumper on PCB. It will cause default Ethernet Setup to below table values:
IP address:
192.168.0.16
Subnet Mask:
255.255.255.0
Default Gateway:
Not implemented = 0.0.0.0
Authentication name:
Gps
Password:
123456
•
Connect Time Server to DC power source, with standard AC/DC adapter. Required is 9..24V DC
voltage with max current consumption 300mA.
Note:
Time server is protected for cross voltage,
but not for high voltage
.
•
Connect Server to nearest Ethernet Switch or Hub with Ethernet cable.
To simple PC Ethernet card crossed cable is needed.
Be sure that your card/switch supports 10Mbit bit rate.
•
Change your Desktop PC Ethernet IP address similarly to
IP:= 192.168.0.1
mask: 255.255.255.0
Without Gateway and
Proxy server
•
Run command <ping 192.168.0.16>
Time Server must respond with ethernet appropriate time delay in [ms].
•
Run HTML browser such Netscape, IE, FireFox
In address line write:
http://192.168.0.16
, Server must reply the main screen:
Summary of Contents for GPS NTP3