background image

24/7 TECHNICAL SUPPORT AT 1.877.877.2269 OR VISIT BLACKBOX.COM

28-PORT 10G 

IP NETWORK 

SWITCH

HARDWARE INSTALLATION GUIDE

EMS10G-28

Summary of Contents for EMS10G-28

Page 1: ...24 7 TECHNICAL SUPPORT AT 1 877 877 2269 OR VISIT BLACKBOX COM 28 PORT 10G IP NETWORK SWITCH HARDWARE INSTALLATION GUIDE EMS10G 28...

Page 2: ...e Selection 13 3 2 Cabinet Placement 13 3 3 Rackmounting 13 3 4 Switch Ground 13 3 5 Fans and Airflow 14 3 6 Power 14 3 7 Storing Components 14 4 INSTALLING THE SWITCH 15 4 1 Unpacking Steps 15 4 2 Ra...

Page 3: ...covery 32 8 TROUBLESHOOTING 34 8 1 Contacting Technical Support 34 8 2 Shipping and Packaging 34 APPENDIX A REGULATORY INFORMATION 35 A 1 USA Federal Communications Commission Statement 35 A 2 NOM Sta...

Page 4: ...handling this equipment WARNING Only trained and qualified personnel can install this equipment Read this guide before you install and power up this equipment This equipment contains two power cords...

Page 5: ...g Algorithms Round Robin Weighted Round Robin Deficit Round Robin Strict Priority Weighted Random Early Detect PERFORMANCE Switching Capacity 960 Gbps Forwarding Capacity 720 Mpps Frame Size 9416 byte...

Page 6: ...G 2 40 G 28 10 G 4 50 G 28 10 G 8 25 G 36 10G The EMS10G 28 side details are as follows 28 fixed 10 G SFP ports 2 fixed 100 G QSFP28 ports 1 7 segment stacking indicator 1 Micro USB console port 2 2...

Page 7: ...anel of the switch Table 2 1 describes its components FIGURE 2 1 FRONT PANEL OF THE SWITCH TABLE 2 1 FRONT PANEL COMPONENTS NUMBER IN FIGURE 2 1 COMPONENT DESCRIPTION 1 28 SFP optical ports SFP module...

Page 8: ...fan modules Provide proper ventilation 2 2 power supply units with integrated fans Provide redundant power 2 5 3 LED INDICATORS The EMS10G 28 includes LED displays on the I O side of the switch This s...

Page 9: ...Blinking green Booting Solid yellow Critical system error Blinking yellow Non critical system error fan failure or power supply failure 5 Power LED Off No power Solid Green Normal Solid yellow POST i...

Page 10: ...e airflow direction when you insert the PSU or fan trays with differing airflows 2 Link LED See Table 2 6 3 PSU LED Off No power Solid green Normal operation Solid yellow Power supply critical event c...

Page 11: ...QSFP28 PORT LEDS NAME OF LED DESCRIPTION Link Activity LED Off No link Solid green Link operating at maximum speed 100G for QSFP28 port Flashing green Link activity operating at maximum speed 100G por...

Page 12: ...a lower speed 40G port Flashing yellow Link activity at a lower speed 40G port Flashing yellow 1 second ON OFF Port beacon TABLE 2 12 QSFP PORT LEDS 4X10G 1G MODE NAME OF LED DESCRIPTION Link Activit...

Page 13: ...om heat sources such as hot air vents or direct sunlight Away from sources of severe electromagnetic noise Inside the restricted access area positioned in a rack or cabinet or on a desktop with adequa...

Page 14: ...onal Electrical Code ANSI NFPA 70 where applicable The switch is powered up as soon as the power cord is connected between the switch and the power source CAUTION Always disconnect the power cable bef...

Page 15: ...ides of the switch WARNING This is a condensed reference Read the safety instructions in your Safety Environmental and Regulatory information booklet before you begin NOTE The illustrations in this do...

Page 16: ...ack for installation of your EMS10G 28 switch You can install the rail system using the 1U tool less method or one of three 1U tooled methods two post flush mount two post center mount or four post th...

Page 17: ...d seat the rear flange rail pegs in the rear vertical post flange In the following illustration item 1 and its extractions show how the pegs appear in both the square and non threaded round holes FIGU...

Page 18: ...ews from each front flange ear on the switch side of the rail and remove each casting Retain the castings for future rack requirements It is not necessary to remove the rear flange castings FIGURE 4 3...

Page 19: ...STALLATION 1 Slide the plunger bracket rearward until it clicks into place and secure the bracket to the front post flange with two user supplied screws item 1 FIGURE 4 4 TWO POST CENTER MOUNT CONFIGU...

Page 20: ...iguration remove the flange ear castings from each end of the rail assemblies To remove the two screws from each flange ear and remove each casting use a Torx driver item 1 Retain the castings for fut...

Page 21: ...nner as the four post configurations 1U FRONT RACK INSTALLATION Configure the rails that are attached to the switch 1 Attach the inner chassis members switch rails to the EMS10G 28 switch Item 3 shows...

Page 22: ...ed Operating Temperature Diagnostics 850 nm Multimode Fiber 300 m CAUTION ESD damage can occur if components are mishandled Always wear an ESD preventive wrist or heel ground strap when handling the E...

Page 23: ...u use sufficient overcurrent protection devices All protective covers are in place Blank panels are installed if you do not install optional modules NOTE Do not power up the switch if you did not inst...

Page 24: ...8 Install the new switch in your rack or cabinet If you are using the fan trays or PSUs from the removed switch reinsert them in the replacement switch 9 Connect all the cables 10 Power on the switch...

Page 25: ...089 Lightning Criteria for Equipment Interfacing with AC Power Ports use an external surge protection device SPD at the AC input of the router PSU LEDs Solid green Input is OK Flashing yellow There is...

Page 26: ...rds before servicing NOTE The PSU slides into the slot smoothly Do not force a PSU into a slot as this action may damage the PSU or the switch chassis NOTE If a PSU fails you must replace the entire u...

Page 27: ...the same airflow direction Environmental factors can decrease the amount of time required between fan replacements Check the environmental factors regularly An increase in temperature and or particula...

Page 28: ...the chassis CAUTION DO NOT mix airflow directions All fans must use the same airflow direction reverse or normal If you mix the airflow direction the switch detects the discrepancy and issues an alar...

Page 29: ...re that your PC has a 9 pin serial port and that you have a terminal emulation program already installed and running on the PC NOTE If your PC s serial port cannot accept a female DB9 connector acquir...

Page 30: ...the USB B console port on the switch 4 Power on the switch 5 Install the necessary USB device drivers To download the drivers contact Black Box Technical Support at 877 877 2269 or info blackbox com...

Page 31: ...nt usb failed No such device or address 4 Add a device to the file systems table fstab and mount the file systems recommended ONIE vi etc fstab FSTAB entry for the ONIE BOOT partition mounted on boot...

Page 32: ...For downloading and updating ONIE from a URL ONIE Embed ONIE For downloading and updating ONIE from a URL and erases any installed O ONIE Diag ONIE Run Diagnostic package for EMS10G 28 Run Black Box N...

Page 33: ...5 255 255 0 To display the IP address use the ifconfig eth0 command as shown ONIE ifconfig eth0 eth0 Link encap Ethernet HWaddr 90 B1 1C F4 9C 76 inet addr 10 11 53 33 Bcast 10 255 255 255 Mask 255 0...

Page 34: ...e will be able to provide more efficient and accurate assistance if you have a complete description including the nature and duration of the problem when the problem occurs the components involved in...

Page 35: ...ation of this equipment in a residential area is likely to cause harmful interference in which case users will be required to take whatever measures necessary to correct the interference at their own...

Page 36: ...tes que impidan el flujo de aire por los orificios de ventilaci n 10 El equipo el ctrico deber ser situado fuera del alcance de fuentes de calor como radiadores registros de calor estufas u otros apar...

Page 37: ...the limits for Class A Information Technology Equipment according to CISPR 22 European Standard EN 55022 The limits for Class A equipment were derived for commercial and industrial environments to pr...

Page 38: ...1st Edition EN 60825 1 Safety of Laser Products Part 1 Equipment Classification Requirements and User s Guide EN 60825 2 Safety of Laser Products Part 2 Safety of Optical Fibre Communication Systems...

Page 39: ...system according to applicable local and national regulations Black Box encourages owners of information technology IT equipment to responsibly recycle their equipment when it is no longer needed Wast...

Page 40: ...e consequential or cost of cover damages resulting from any errors in the product information or specifications set forth in this document and Black Box Corporation may revise this document at any tim...

Page 41: ...____ __ ________________________________________________________________________________________________ __ ____________________________________________________________________________________________...

Page 42: ...____ __ ________________________________________________________________________________________________ __ ____________________________________________________________________________________________...

Page 43: ...____________ __________________________________________________________________________________________________ ________________________________________________________________________________________...

Page 44: ...NEED HELP LEAVE THE TECH TO US LIVE 24 7 TECHNICAL SUPPORT 1 877 877 2269 COPYRIGHT 2018 BLACK BOX CORPORATION ALL RIGHTS RESERVED EMS10G 28_INSTALL_REV1 PDF...

Reviews: