background image

Description:

The 

DFCS

 Redundant Fast Ethernet manageable media

converters are members of the modular 

DFCS

  product

family. The following models are described:

100Tx-2Fx

: 100Base-Tx UTP to dual 100Base-Fx dual fiber

100Tx-2Tx

: 100Base - Tx UTP to dual 100Base-Tx UTP

The 

DFCS 

Redundant Fast Ethernet modules are intended

for  use  in  networks  that  require  fiber  or  copper  link

redundancy. During normal operations Port A is the active

primary and Port B is the backup secondary. When loss of

link on Port A is detected, the module automatically switches

to  transmitting  on  Port  B.  With  a  switch  over  time

of less than 100 microseconds, these modules provide

the  rapid  response  time  required  for  ultra  critical

applications. Note: After the link is switched, there will be

a 5 second delay before that link can been reestablished.

Application Examples:

Fig 1: Redundant Switch Example

In  this  example,  redundant  Switches  1  and  2  are

connected  to  Switch  3  via  a  100Tx-2Fx  converter.    If

power fails in Switch 1, or if  there is a loss of link in the

fiber  cable,  the  100Tx-2Fx  converter  switches  to

transmitting on port B and routes data flow to Switch 2.

Fig  2:  Redundant  Fiber  to  Customer

In  this  example,  data  flow  from  a  core  switch  at  the

Central  Office  is  converted  from  UTP  to  redundant

fiber, and converted back to UTP, where it is connected

to an edge switch at the Customer Premises.  If there is

a loss of link in fiber Port A, the 100Tx-2Fx converter

switches to transmitting on fiber Port B, without a service

disruption to the mission-critical customer.

Link Modes:

In  order  to  accommodate  different  user  needs,  the

Redundant DFCSs support four different linking modes.

It is recommended keeping the Redundant 

DFCSs

 

in

the factory default Link Segment (LS) setting.

Fig 3: Link Segment Mode

In “Link Segment” (LS), sometimes referred to as the

“Normal”  mode,  a  port  transmits  a  “Link”  signal

independently of any received “Link” at any other port.

For example, the UTP transmits a “Link” regardless of

the fiber receiving a “Link” [Fig 2(a) & (b)].  Figure 2(a)

shows the state when all links are functioning correctly.

Port A LEDs indicate link and activity, while the Port B

LEDs blink at one Hertz to indicate they are not active,

but are in “Standby”.  Figure 2(b) shows that when the

fiber link to Port A is broken, Port B becomes active.

Page 1

Page 2

Page 3

Page 4

In “Link Propagate” (LP), sometimes referred to as  “Link

Loss  Carry  Forward”,  a  port  transmits  a  “Link”  signal

only  when  receiving  a  “Link”  at  its  other  port.  For

example, the UTP transmits a “Link” only when receiving

a “Link” at the fiber port (Not Shown).
In  “Remote  Fault  Detection”  (RFD),  the  UTP  port

transmits a “Link” signal only when receiving a “Link” at

the  fiber  port.  The  fiber  port  transmits  a  “Link”  only

when receiving “Link” signals both at the fiber port and

the UTP port. As a result, fiber faults (no “Link” received

at the fiber) are looped-back and can be reported to the

network’s core (Not Shown).
In  “Symmetrical  Fault  Detection”  (SFD),  the  UTP  port

transmits a “Link” signal only when receiving a “Link” at

the fiber port. The fiber port transmits a “Link” only when

receiving “Link” signal both at the fiber port and the UTP

port. As a result, fiber faults (no “Link” received at the fiber)

are looped back and can be reported to the network core. In

addition, connecting two back-to-back converters which are

both set to SFD facilitates dual-loop-back where fiber faults

are reported to both ends of the network (Not Shown).

Board Mounted Dip-Switch Settings:

Fig 4: Board Mounted Dip-Switches

“LS/LP” Link Segment

/

Propagate Dip-Switch:

This dip-switch controls Link Propagation (LP, sometimes

referred to as LLC--Link Loss Carry Forward) or Link Segment

(LS). In the “ON” position, LP mode is enabled.  When in the

“OFF” position (factory default), LS mode is enabled.

Note that for “LS”  mode,  “LP”,  “RFD”  and  “SFD”,

dip-switches  must  be  in  the  Left  position  (factory

setting).
Note that setting more than one of the mode switches

(“LP”, “RFD” or “SFD”) to the Right position on the

same  module  is  an  illegal  mode  that  will  result  in

unpredictable  behavior.
“RFD” Remote Fault Detection:

When in the “RFD” position, the Remote Fault Detection

(RFD) mode is enabled.

Connecting  two  converters  with  both  set  to  RFD

mode is illegal and will cause a “deadly embrace”

lockup.

“SFD” Symmetrical Fault Detection:

When  in  the  “SFD”  position,  the  Symmetrical  Fault

Detection (SFD) mode is enabled. Note that for the 

DFCS

Redundant  Fast  Ethernet  modules  when  loss  of  “Link”

occurs between two modules, both redundant connections

must have a loss of incoming “Link” signal in order for this

to occur.

“AN/MAN” UTP Auto/Manual Switch:

Setting this dip-switch to “Auto” (factory setting) enables the

UTP Port C to determine the mode automatically. This feature

allows connections with devices that do not auto-negotiate

properly.

“FD/HD” UTP Full/Half Duplex Switch:

When the “Auto/Manual” dip-switch is in “Manual” position,

the “UTP Full/Half Duplex” dip-switch determines the duplex

operation  mode  for  the  UTP  port.    When  set  to  “Full

Duplex” (factory setting), the UTP port will operate in full

duplex. When set to “Half Duplex” the UTP port will operate

in half duplex.  Adjust the half/full-duplex switch to match

the connecting device and check for link status.

“RTA/NR” Return to Port A Switch:

When the “Return to Port A” switch is in “RTA” position (factory

default), link reestablishment on Port A will immediately return

Page 5

Page 6

DFCS 100Tx-2Fx Dual Fiber Modules

Connector

Type

Distances

ST

SC

MM

5km

LMC3044C

LMC3047C

SM

30km

LMC3045C

LMC3048C

SM

60km

LMC3046C

LMC3049C

DFCS 100Tx-2Tx

 

Dual Fiber Modules

Connector

Type

Distances

RJ-45

UTP

100m

LMC3043C

Dynamic  Fiber  Conversion  System

100Tx-2Fx & 100Tx-2Tx User Manual

Order 

toll-free

 in the U.S.: Call 

877-877-BBOX

(outside U.S. call 

724-746-5500

)

FREE technical support 24 hours a day, 7 days

a week; Call 

724-746-5500

 or  fax 

724-746-0746

Mailing address: 

Black Box Corporation

,

1000 Park Drive, Lawrence, PA 15055-1018
Web site: 

www.blackbox.com

E-mail: 

[email protected]

CUSTOMER

SUPPORT

INFORMATION

Page 10

Page 11

LED Indicators:
LED

Color

Description

Power:

Yellow

On--Power

Port A Link:

Green

On--Link  /  Blink--activity

Steady Blink--Standby mode

Port B Link:

Green

On--Link  /  Blink--activity

Steady Blink--Standby mode

Port C Link:

Green

On--Link  /  Blink--activity

Port A Select:

Green

On--Active port / Blink--remote

side broken

Port B Select:

Green

On--Active port / Blink--remote

side broken

UTP Auto:

Green

On--Auto-Negotiation enabled

UTP FDx:

Green

On--Full-Duplex detected

Page 9

Page 8

data transmission to Port A.  When the switch is set to “NR”,

Port B will continue to be used for transmitting data even after

link has been reestablished on Port A.

Note that modules connected together must be set to

the same mode for correct operation.
“RJ45 Cross-Over” Switch (not shown):

When connecting the UTP to a hub or switch, set switch to

“Straight-Through” (factory setting). When connecting to a

workstation, set to “Cross-Over.”

Mounting and Cable Attachment:

DFCS

 modules are hot-swappable and can be installed

into  any  chassis  in  the 

DFCS

  family.

1. Carefully slide the 

DFCS

 module into the installation

slot, aligning the module with the installation guides.

NOTE: Ensure that module is firmly seated against

the backplane.

2. Secure  the  module  by  securing  the  panel  fastener

screw (attached to module) to chassis front.

3. Attach the UTP port of Port C via a category 5 cable

to a 100Base-Tx Ethernet device.

4.

DFCS

 Redundant Fast Ethernet Modules should be

deployed in pairs with Port A linked to Port A and Port

B linked to Port B between the two modules. If using

DFCS

 Redundant Fast Ethernet Modules with redundant

Fx or Fx SF ports, attach Port A fiber ports and Port

B fiber ports of the two modules via an appropriate

multimode  or  single-mode  fiber  cable.  The 

DFCS

transmit  (Tx)  must  attach  to  the  receive  side  on

other  device;  the  receive  (Rx)  must  attach  to  the

transmit.  If  using 

DFCS

  Redundant  Fast  Ethernet

Modules  with  redundant  Tx  ports,  attach  the  UTP

ports  of  the  two  modules’  Port  A  via  a  category  5

cable and UTP ports of the two modules’ Port B via

a category 5 cable.

Page 12

Page 7

040-L3043-001A  12/03

TRADEMARKS

All applied-for and registered trademarks are the property

of their respective owners.

FEDERAL COMMUNICATIONS COMMISSION AND

CANADIAN DEPARTMENT OF COMMUNICATIONS

RADIO FREQUENCY INTERFERENCE STATEMENTS

This  equipment  generates,  uses,  and  can  radiate  radio

frequency  energy  and  if  not  installed  and  used  properly,

that  is,  in  strict  accordance  with  the  manufacturer’s

instructions,  may  cause  interference  to  radio

communication. It has been tested and found to comply

with the limits for a Class A computing device in accordance

with  the  specifications  in  subpart  B  of  Part  15  of  FCC

rules, which are designed to provide reasonable protection

against such interference when the equipment is op-

erated  in  a  commercial  environment.  Operation  of  this

equipment in a residential area is likely to be cause inter-

ference, in which case the user at his own expense will be

required to take whatever measures may be necessary to

correct the interference.
Changes or modifications not expressly approved by the

party  responsible  for  compliance  could  void  the  user’s

authority to operate the equipment.

This digital apparatus does not exceed the Class A limits

for radio noise emission from digital apparatus set out in the

Radio  Interference  Regulation  of  the  Canadian

Department of Communications.
Le  présent  appareil  numérique  n’émet  pas  de  bruits

radioélectriques  dépassant  les  limites  applicables  aux

appareils numéirques de las classe A prescrites dans le

Règlement sur le brouillage radioélectrique publié par le

ministère des Communications du Canada.

©Copyright 2003. Black Box Corporation. All rights reserved.

1000  Park  Drive 

·

  Lawrence,  PA  15055-1018

724-746-5500 

·

  Fax  724-746-0746

NORMAS OFICIALES MEXICANAS (NOM)

ELECTRICAL SAFETY STATEMENT

1. Todas las instrucciones de seguridad y operación deberán ser leídas

antes de que el aparato  eléctrico sea operado.

2. Las instrucciones de seguridad y operación deberán ser guardadas

para referencia futura.

3. Todas las advertencias en el aparato eléctrico y en sus instrucciones

de operación deben ser respetadas.

4. Todas las instrucciones de operación y uso deben ser seguidas.

5. El aparato eléctrico no deberá ser usado cerca del agua—por

ejemplo, cerca de la tina de baño, lavabo, sótano mojado o cerca de

una alberca, etc.

6. El aparato eléctrico debe ser usado únicamente con carritos o

pedelstales que sean recomendados por el fabricante.

7. El aparato eléctrico debe ser montado a la pared o al techo sólo

como sea recomendado por el fabricante.

8. Servicio—El usuario no debe intentar dar servicio al equipo eléctrico

más allá a lo descrito en las instrucciones de operación. Todo otro servicio

deberá ser referido a personal de servicio calificado.

9. El aparato eléctrico debe ser situado de tal manera que su posición

no interfiera su uso. La colocación del aparato eléctrico sobre una

cama,  sofá,  alfombra  or  superficie  similar  puede  bloquea  la

ventilación, no se debe colocar en libreros o gabinetes que impidan

el flujo de aire por los orificios de ventilación.

10. El equipo eléctrico deber ser situado fuera del alcance de fuentes de

calor como radiadores, registros de calor, estufas u ostros aparatos

(incluyendo amplificadores) que producen calor.

11. El aparato eléctrico deberá ser connectado a una fuente de poder sólo

del tipo descrito en el instructivo de operación, o como se indique en el

aparato.

12. Precación debe ser tomada de tal manera que la tierra fisica y la

polarización del equipo no sea eliminada.

13. Los cables de la fuente de poder deben ser guiados de tal manera que

no sean pisados ni pellizcados por objetos colocados sobre o contra

ellos, poniendo particular atención a los contactos y receptáculos

donde salen del aparato.

14. El equipo eléctrico debe ser limpiado únicamente de acuerdo a las

recomendaciones del fabricante.

15. En caso de existir, una antena externa deberá ser localizada lejos de

las lineas de energia.

16. El cable de corriente deberá ser desconectado del cuando el equipo

no sea usado por un largo periodo de tiempo.

17. Cuidado debe ser tomado de tal manera que objectos liquidos no

sean derramados sobre la cubierta u orificios de ventilación.

18. Servicio por personal calificado deberá ser provisto cuando:

A: El cable de poder o el contacto ha sido dañado; u

B: Objectos han caído o líquido ha sido derramado dentro del aparato;

o

C: El aparato ha sido expuesto a la lluvia; o

D: El aparato parece no operar normalmente o muestra un cambio

en su desempeño; o

E: El aparto ha sido tirado o su cubierta ha sido dañada.

SPECIFICATIONS

Model

100Tx-2Fx

100Tx-2Tx

Protocols

100Base-Fx,

100Base-Tx

100Base-Tx

Copper Connectors

RJ-45

RJ-45

Fiber Connectors

SC, ST

-

Controls

UTP X-over, LS/LP,

RFD, SFD, UTP

Auto/Man, FD/HD

UTP X-over, LS/LP,

RFD, SFD, UTP

Auto/Man, FD/HD

LED Displays

Pwr, FO link,

UTP link, SEL, Auto,

FD/HD, RTA

Pwr, UTP link,

SEL, Auto,

FD/HD, RTA

Dimensions

W:0.85" x D:4.5" x

H:2.8"

W:0.85" x D:4.5" x

H:2.8"

Weight

8 oz.

8 oz.

Compliance

UL, CE, FCC

Class A

UL, CE, FCC

Class A

Temperature
-Operating
-Storage

0 to 50 C

-40 to 80 C

0 to 50 C

-40 to 80 C

Altitude

0-10,000 ft

0-10,000 ft

MTBF (hrs)

1,175,000

1,235,000