9
ASYNC MP LINE DRIVER CARD
3.2 Quick Setup Instructions
For most applications, you will not need an in-depth knowledge of the Card’s
capabilities to get up and running. The following quick-setup DIP-switch
configurations cover most Async MP Line Driver Card operating environments.
3.2.1 P
OINT
-
TO
-P
OINT
A
PPLICATIONS
If you are installing these units in a point-to-point application with a computer,
printer or terminal, configure the DIP switches on both Cards as follows:
Switch Number
1
2
3
4
5
6
7
Positions
OFF
OFF
OFF
ON
ON
ON
OFF
3.2.2 M
ULTIPOINT
A
PPLICATIONS
If you are installing these units in a multipoint application, configure the DIP
switches for master and slave units as follows:
Switch Number
1
2
3
4
5
6
7
Master positions
ON
ON
ON
OFF
OFF
OFF
OFF
Slave positions
ON
ON
ON
OFF
OFF
OFF
ON