5.2 Resetting a unit
On the left side of the front panel of each unit, you will find a small hole
which is used to invoke special functions. Use a thin implement, such as a
straightened paperclip to press and hold the button concealed behind the
smaller hole. Depending on when you release the button, the unit will
either perform a normal reset, enter a special serial upgrade mode (not the
usual method of upgrading - See the Maintenance page) or completely
reset itself to factory defaults:
Time
(seconds):
0 . . . . 5 . . . . 10 . . . . 15 . . . .
Indicator(s):
PWR:
All:
All:
All:
On
Alternate
flashing
Rapid
flashing
together
Normal
Release button for:
Normal
restart
Serial
upgrade
Reset
to
Return
to
(contact
technical
support)
factory
defaults
normal