background image

Sandwich/Fry Warmer 

 

Maintenance 

 

 

14 

4.  Allow the equipment to cool to room temperature. 

 

5.  Remove and clean the Fry Warmer blower pan and pan insert.  

 

6.  Clean around the slotted holes at the air discharge on the blower box.  

 

7.  Clean the air intakes using a mild soap and water solution. 

 

8.  Sponge the inside and outside of the unit with a mild soap and water solution, being sure to clean all 

areas. Avoid getting water in the interior of the unit. 
 

9.  Wipe the parts and unit dry with a soft, clean cloth and replace the blower pan and pan insert. 

Troubleshooting 

Problem Cause 

Possible 

Solution 

Sandwich Warmer and/or 
Fry Warmer will not turn on. 

Power cords not 
connected or circuit 
breaker supplying power 
to the unit has tripped. 

Make sure power cords are connected and circuit 
breaker is on. If problem persists contact a 
licensed electrician. 

Product is not holding it’s 
temperature 

Product temperature is 
too low when loaded. 
 
Or  
 
Faulty component in 
heating circuit 

Make sure product is above 160

°

 F when loaded. 

 
 
 
 
Contact an authorized BKI service agent for 
corrective action. 

Fry Warmer

 

Warmer chute is not 
heating and perforated pan 
is not heating 

No power to unit. 

Make sure that the circuit breaker at the power 
supply is on and the Fry Warmer main power 
switch is on. If problem persists, contact licensed 
electrician. 

Warmer chute is heating 
and the perforated pan is 
not heating 

Fan has overheated and 
cut off 
 
Or 
 
Heating coil has failed 

Wipe the dust from the air intake louvers to allow 
proper airflow and prevent fan overheating. Turn 
the power switch off. Wait 60 seconds. Turn the 
power switch back on. 
 
Contact an authorized BKI service agent for 
corrective action. 

Noisy fan 

Fan blade is dirty or fan 
bearings are failing 

Contact an authorized BKI service agent for 
corrective action. 

Warmer chute is not 
holding heat 

Ceramic heating 
element failure 

Contact an authorized BKI service agent for 
corrective action. 

Sandwich Warmer

 

Warmer is not heating 

No power to unit 
 
 
 
 
Or 
 
Faulty component in top 
or bottom heating circuit. 

Make sure that the circuit breaker at the power 
supply is on and the Sandwich Warmer main 
power switch is on. If problem persists, contact 
licensed electrician. 
 
 
 
Contact an authorized BKI service agent for 
corrective action. 

Summary of Contents for Sandwich/Fry Warmer FW-15L

Page 1: ...Sandwich Fry Warmer MODELS SFW FW 15L Installation Operation Manual Serial Numbers 121866 and Higher ...

Page 2: ...ville South Carolina or F O B authorized BKI Distributor The Company and or its authorized representatives will assume the normal replacement labor expense for the defective part for the period of the warranty as stated above excluding travel and or other expenses incidental to the replacement of the defective part where replacement work is performed during standard business hours and not subject ...

Page 3: ...tup and Preheating 7 SFW 7 FW 15L 8 Sandwich Warmer Temperature Adjustment 8 Operational Guidelines 8 Unit Shutdown 8 SFW 8 FW 15L 8 Installation 9 Instructions For Shipping Damage 9 Electrical Information And Grounding 9 Installation Instructions 9 Right Sided SFW 9 Left Sided SFW 10 FW 15L 11 Maintenance 13 Scheduled Maintenance 13 SFW Cleaning 13 FW 15L Cleaning 13 Troubleshooting 14 Repair 15 ...

Page 4: ...elow is the safety alert symbol When you see this symbol on your equipment be alert to the potential for personal injury or property damage Safety Signs and Messages The following Safety signs and messages are placed in this manual to provide instructions and identify specific areas where potential hazards exist and special precautions should be taken Know and understand the meaning of these instr...

Page 5: ...allow children to play near or operate your equipment Keep Safety Labels Clean and in Good Condition Do not remove or cover any safety labels on your equipment Keep all safety labels clean and in good condition Replace any damaged or missing safety labels Refer to the Safety Labels section for illustration and location of safety labels on this unit If you need a new safety label obtain the number ...

Page 6: ...our employees are aware of the safety precautions on the equipment and in this manual Make certain that you have thoroughly trained your employees about operating the equipment safely Make certain the equipment is in proper working condition If you make unauthorized modifications to the equipment you will reduce the function and safety of the equipment ...

Page 7: ...Sandwich Fry Warmer Introduction 5 Safety Labels ...

Page 8: ...Sandwich Fry Warmer Operation 6 Operation Controls and Indicators ...

Page 9: ...TOM HEAT temperature control Controls the temperature of the Lower Sandwich Warmer heating element 9 Lower Sandwich Warmer BOTTOM HEAT pilot light Cycles on and off to indicate when the Lower Sandwich Warmer heating element turns on and off 10 Sandwich Warmer POWER ON OFF Switch Controls power to the upper and lower Sandwich Warmers 11 Fry Warmer ON OFF Switch Controls power to the entire Fry Warm...

Page 10: ... F before being placed in the warmer Foods loaded in first should be served first as much as is practical Check Federal and State Health and Sanitation Regulations for internal temperature required for holding cooked foods for sale Maintaining these temperatures often tends to continue to cook certain products Therefore smaller amounts of bulk foods should be displayed at non peak periods and the ...

Page 11: ...ine Electrical Information And Grounding Electrocution equipment failure or property damage could result if an unlicensed electrician performs the electrical installation Ensure that a licensed electrician perform the electrical installation in accordance with local codes or in the absence of local codes with the National Electrical Code ANSI NFPA 70 20XX This unit when installed by an authorized ...

Page 12: ...blower pan Left Sided SFW 1 Obtain a suitable countertop location and place the entire unit in position 2 Measure mark and cut a hole in the countertop for the Fry Warmer blower pan to fit in according to the following drawing 3 Place the blower pan into the hole making sure that open side of the pan fits over the two tabs on the louvered blower box 4 Place the perforated pan insert into the blowe...

Page 13: ...vered blower box will be positioned for the power cord to pass through 4 Position collar weldment into the cutout area with slotted holes toward the main unit 5 Position the main unit as shown above ensuring that the side panel flanges are under the flanges of the collar weldment 6 Line up the back attachment holes on the flanges of the main unit with the slotted holes in the flanges of the collar...

Page 14: ...eet metal screws 10 Feed power cord supplied down through hole in countertop 11 Reattach louvered blower box to main unit 12 Seal main unit to the countertop to conform to NSF Standard 4 Item 4 28 Dow Corning RTV 732 Multi purpose Sealant 13 Place the blower pan into the hole making sure that open side of the pan fits over the two tabs on the louvered blower box 14 Place the perforated pan insert ...

Page 15: ...ly by applying compressed air Do not leave this unit on and unattended after business hours SFW Cleaning 1 Remove all food from the unit 2 Place the Fry Warmer ON OFF switch to the OFF 0 position 3 Place the Sandwich Warmer POWER ON OFF switch to the OFF 0 position 4 Unplug both power cords 5 Allow the equipment to cool to room temperature 6 Remove and clean the Fry Warmer blower pan and pan inser...

Page 16: ...horized BKI service agent for corrective action Fry Warmer Warmer chute is not heating and perforated pan is not heating No power to unit Make sure that the circuit breaker at the power supply is on and the Fry Warmer main power switch is on If problem persists contact licensed electrician Warmer chute is heating and the perforated pan is not heating Fan has overheated and cut off Or Heating coil ...

Page 17: ...ake sure the power has been turned off and the unit has cooled down Lamp Replacement Only use Teflon coated lamp to prevent glass contamination 1 Make sure power to the unit is OFF and the unit has cooled down 2 Carefully remove the faulty lamp 3 Replace with the new lamp ...

Page 18: ...Sandwich Fry Warmer Notes 16 Notes ...