Ventless Hood System
Installation
12
1. Route incoming power lines through holes located in the top of the 12”x8”x4” electrical enclosure.
2. Connect ground to the lug provided inside the enclosure.
3. Perform the applicable step below:
For single-phase operation, connect incoming power to terminals L1 and L2 of the contactor.
For three-phase operation, connect incoming power to terminals L1, L2 and L3 of the
contactor.
5. Replace electrical box cover.
6. Insert plug into receptacle located in the hood.
7. Install cover over plug.
Appliance Electrical Connection
This connection is for appliances requiring a Listed flexible conduit connections.
1. Remove receptacle and four wires (T1, T2, T3, and Ground).
2. Cover junction box hole with provided plate and hardware removed from receptacle.
3. Remove hole plug from hole in bottom of electrical enclosure and install conduit from appliance
utilizing appropriate Listed fitting (not provided).
4. Wire appliance according to the electrical diagram in this manual.
5. Replace all panels and install cover over hole that was provided for the receptacle (now removed)