background image

 

Ventless Hood System

  

MODEL FH-28WM WALL-MOUNT 
Operation & Installation 

Serial Numbers 120646 and Higher

 

 
 
 

 

 
 

Summary of Contents for FH-28WM

Page 1: ...Ventless Hood System MODEL FH 28WM WALL MOUNT Operation Installation Serial Numbers 120646 and Higher ...

Page 2: ...round trip and 2 hours travel time and performed during regular weekday business hours EXCEPTIONS Any exceptions must be pre approved in advance and in writing by BKI The extended door warranty on convection ovens years 3 through 5 is a parts only warranty and does not include labor travel mileage or any other charges EXCLUSIONS Negligence or acts of God Thermostat calibrations after 30 days from ...

Page 3: ...stallation 8 Unpacking and Handling 8 Inspection for Shipping Damage 8 Location and Clearance 8 Assembly and Mounting 8 Air Deflector 8 Fire Damper 9 Particle Odor Filter 9 Restraining Device 9 Fire Extinguishing System 10 Wiring 11 Standard Electrical Connection 11 Appliance Electrical Connection 12 Operation 13 Principle of Operation 13 Preparation 13 Start Up 13 Shut Down 13 When to Replace the...

Page 4: ...low is the safety alert symbol When you see this symbol on your equipment be alert to the potential for personal injury or property damage Safety Signs and Messages The following Safety signs and messages are placed in this manual to provide instructions and identify specific areas where potential hazards exist and special precautions should be taken Know and understand the meaning of these instru...

Page 5: ...igned for this application only other filters will not work properly Use only a BKI particle odor filter Safe Work Practices Beware of High Voltage This equipment uses high voltage Serious injury can occur if you or any untrained or unauthorized person installs services or repairs this equipment Always Use an Authorized Service agent to Service Your Equipment Keep this manual with the Equipment Th...

Page 6: ...t and a fire extinguisher near the equipment You must use a 40 pound Type BC fire extinguisher and keep it within 25 feet of your equipment Keep emergency numbers for doctors ambulance services hospitals and the fire departments near your telephone Know your responsibility as an Employer Make certain your employees know how to operate the equipment Make certain your employees are aware of the safe...

Page 7: ...e links to be UL Listed 165 F load rating 3 45 lbs Pressure Open Fryers Pressure fryers acceptable for use with this hood shall be constructed such that when the lid is released or unlatched it shall spring to the fully open position within four seconds Fully open is defined as vertical upright position 80 or more from the closed position The lid must open without operator or electrical assistance...

Page 8: ...ture 375 F 191 C Maximum shortening capacity 110 lbs 50kg Maximum cooking surface area 396 sq in 2555 sq cm USE ELECTRIC FRYERS AND SINGLE VAT FRYERS ONLY Griddles Specifications Volts 208 240 Phase 1 or 3 Maximum Amps 38 5 Maximum Input 8 KW Frequency 60 Hz Maximum griddle surface area 450 sq in 2903 sq cm Maximum cooking surface temperature 450 F 232 C USE ELECTRIC GRIDDLES ONLY ...

Page 9: ...Ventless Hood System Introduction 7 Safety Labels ...

Page 10: ...material MUST be retained to show the inspector from the shipping line Location and Clearance Place the Filter Hood in a location with clearance according to the data below These distances provide for proper clearance to combustible surfaces access for maintenance and proper air flow from hood exit vent MINIMUM CLEARANCE HOOD TO COMBUSTIBLE 18 in SIDES 0 in BACK 0 in TOP 0 in BOTTOM NON COMBUSTIBL...

Page 11: ...corner carefully slide the filter into the unit 4 Close and latch the door Restraining Device Install restraining device to secure the appliance to the wall Adjust restraining cable to allow no more than two inches 2 of appliance movement In the event of an appliance fire serious injury property damage or death could occur if the appliance is not secured to the hood A restraining device has been p...

Page 12: ...rd Technical Service Specialist Badger Fire Protection 4251 Seminole Trail Charlottesville Va 22911 Office 800 446 3857 ext 111 Fax 434 974 4113 Mobile 434 981 0505 1 After the hood has been properly secured to prevent movement locate the end of line remote pull station at a point of egress or exit in a manner approved by the local authority and in accordance with applicable codes To install the e...

Page 13: ...an performs the electrical installation Ensure that a licensed electrician perform the electrical installation In the event of an appliance fire serious injury property damage or death could occur if the appliance is powered from a source other than the hood The cooking appliance used under this hood MUST receive its input power from the hood In the event of a fire the hood fire extinguishing syst...

Page 14: ...r 6 Insert plug into receptacle located in the hood 7 Install cover over plug Appliance Electrical Connection This connection is for appliances requiring a Listed flexible conduit connections 1 Remove receptacle and four wires T1 T2 T3 and Ground 2 Cover junction box hole with provided plate and hardware removed from receptacle 3 Remove hole plug from hole in bottom of electrical enclosure and ins...

Page 15: ...red air then passes through the blower and is returned to the room Preparation The following conditions must be met for the Filter Hood to function The particle odor filter must be installed The grease baffle must be installed The filter door must be shut The fire extinguisher system must be active Power must be supplied to the hood The fire damper must be open with link installed see page 8 Start...

Page 16: ...o medium volume applications the filter may need replacement prior to the CHANGE FILTER light illuminating If you smell a strong odor coming from the face of the filter and the CHANGE FILTER light is not illuminated the filter needs to be replaced If necessary refer to the procedure in this manual for replacing the filter see page 16 Cleaning Refer to scheduled maintenance in this manual see page ...

Page 17: ...ning the baffle Weekly User Particle Odor Filter Inspect particle odor filter In low to medium volume applications the filter may need replacement prior to the indicating light turning on This condition will be evident by a strong odor coming from the face of the filter If necessary refer to the procedure in this manual for replacing the filter Monthly User Door and Filter Interlock Check door and...

Page 18: ...unit 2 Open the filter door on the front of the unit by rotating the handle counter clockwise 3 Slide the used filter out of the unit 4 Remove the replacement filter from the plastic bag 5 Observing the UP arrows on the filter with a hand at each front corner carefully slide the filter into the unit When installing a new filter slight resistance should be observed as the filter is being slid into ...

Page 19: ...Ventless Hood System Notes 17 Notes ...

Page 20: ...P O Box 80400 Simpsonville S C 29680 0400 USA http www bkideas com Made and printed in the U S A LI0222 0908 ...

Reviews: