E.  GAS  CONNECTIONS:

The  ovens  should  not  be  installed  on  the  same  gas  line  with  space  heaters,  boilers  or  other  gas  equipment 
with  high  intermittent  demand.

The  installation  of  this  oven  must  conform  with  the  latest  local  codes  or 

Nationa/Fuel  Gas  Code.  ANSI 

Z223.1,  Natural  Gas  Installation  Code.  CAN/CGA-BJ49.1.  or  the  Propane  Installation  Code.  CAN/CGA-
BJ49.2

The  appliance  must  be  isolated  from  the  gas  supply  piping  system  by  closing  it’s  manual  shut-otf  valve 
during  any  pressure  testing  of  the  gas  supply  piping  system  at  test  pressures  equal  to  or  less  than  ½  psi 
(3.45kPa).  The  appliance  and  its  shut-off  valve  must  be  disconnected  from  the  gas  supply  piping  system 
during  any  pressure  testing  of  that  system  at  test  pressures  in  excess  of    ½

   

psig  (3.45kPa).

Use  a  pipe  joint  compound  that  is  resistant  to  the  action  of  liquefied  petroleum  gases  when  making  gas 
Connections.  For  Propane  gas,  use  at  least  1/

2" 

(13  mm)  pipe  or  tubing  with  a  5/8"  (16  mm)  inside  diameter. 

For  Natural  gas,  use  3/4"  (19  mm)  pipe.

The  gas  pressure  regulator  is  part  of  the  combination  valve  and  is  adjusted  to  yield  a  pressure  of  3.5"  water 
column  (9mbar)  for  Natural  Gas.  If  the  oven  is  ordered  for  use  on  Propane  Gas  or  Butane  the  pressure 
regulator  in  the  combination  valve  is  preset  at  the  factory  to  yield  a  pressure  of  10"  water  column  (25  mbar).

Gas  supply  pressure  in  the  European  Community  countries  should  be  as  below:
Gas  Type

Supply  Pressure

G20 

20  mbar

G25

25  mbar

G20/25

20/25  mbar 

G30

30  or  50  mbar  depending  on  country 

G31

30,  37,  or  50  mbar  depending  on  country

 
A  separate  shut-off  valve  for  each  oven  must  be  provided.  It  should  be  as  close  as  possible  to  the  place 
where  the  gas  line  goes  into  the  oven.  It  must  be  located  such  that  it  is  easily  accessible.  When  stacking  with 
another  oven,  two

 

shut-off  valves,  one  for  each  of  the  two  ovens,  must  be  provided.

After  the  Gas  Supply  has  been  connected,  it  is  extremely  important  to  check  all  the  piping  for  leaks. 
Use  a  soap  and  water  solution  or  a  product  expressly  made  for  this  purpose.  Do  not  use  Matches, 
Candles  or  a  Flame  etc  to  check  leaks  since  these  methods  are  extremely  dangerous.

F.  ELECTRICAL  CONNECTION:

The  oven  when  installed  must  be  electrically  grounded  in  accordance  with  local  codes/and/or  the  latest 
edition  of  the  National  Electrical  Code  ANSI/NFPA  No.  70  in  the  USA  (Canadian  Electrical  Code  CSA 
Standard  C22.I,

 

Part  1  in  Canada).

In  Europe,  the  appliance  must  be  connected  by  an  earthing  cable  to  all  other  units  in  the  complete 

4

Suitable  for  installation  on  combustible  floor  when  installed  with  legs  or  casters 
provided.

!

!

!

!

CAUTION:

  Do  not  set  the  oven  with  its  back  flat  against  the  wall.  It  will  not  operate 

properly  unless  there  is  at  least  three  inches  breathing  space  behind  the  oven.

MINIMUM  CLEARANCES  FROM  COMBUSTIBLE  AND  NON-COMBUSTIBLE  CONSTRUCTION

                                                                                                Under  Ventilation  Hood                                                                         Direct  Venting
        RIGHT  WALL

1”

1"

        LEFT  WALL

1"

3"

        REAR  WALL

3"

3"

q

Summary of Contents for CO1-G

Page 1: ...xposure to smoke or fumes may cause nausea or dizziness Note Only Pizza or Bread can have direct contact with ceramic decks All other food products must be placed in a pan or container to avoid direct contact with ceramic decks This equipment has been engineered to provide you with year round dependable service when used according to the instructions in this manual and standard commercial kitchen ...

Page 2: ... supplied for stacked installations A carton containing a Flue Adapter and or an optional Draft Hood for Direct Venting Not available for European Community Countries B SET UP MOUNTING NOTE This appliance must be installed by competent person in accordance with the rules in force In the U K Corgi registered installers including the regions of British Gas undertake to work to safe and satisfactory ...

Page 3: ...lts 3 Insert Open Rack Shelf and tighten into place with eight 3 8 16 screws washers and nuts 4 Position Rack Supports and tighten in place using 4 each of Flat washers and 5 16 18 Hex Nuts To assemble over a Base Cabinet 1 Tilt cabinet over onto the left hand side Attach two mounting plates to the right underside and screw 6 legs into the center holes 2 Lift up left hand side of the base cabinet ...

Page 4: ...e European Community countries should be as below GasType Supply Pressure G20 20 mbar G25 25 mbar G20 25 20 25 mbar G30 30 or 50 mbar depending on country G31 30 37 or 50 mbar depending on country A separate shut off valve for each oven must be provided It should be as close as possible to the place where the gas line goes into the oven It must be located such that it is easily accessible When sta...

Page 5: ...anges on the outside of the flue stack extending out of the building The flue pipe from the draft hood must not run downwards at any point from the oven to the final outlet It should always slant slightly upwards For best results it should rise straight up NOTE DO NOT PUT A DAMPER IN THE FLUE AND DO NOT CONNECT A BLOWER DIRECTLY TO THE FLUE If the flue runs directly to the free air outside the bui...

Page 6: ...n when done B TIMED COOKING ROTARYCONTROL I Close the oven doors 2 Turn Selector Switch to HI or LO position The indicator light near the Selector Switch will be illuminated 3 Turn the thermostat knob to the desired cooking temperature 4 Upon reaching the set temperature the indicator light near the thethermstat will go out 5 Load the oven with product to be cooked 6 Turn the timer knob to the des...

Page 7: ... NOT USE STEELWOOL Clean The Stainless Steel Interior Baked on splatter oil grease or discoloration on the stainless steel inside of the oven may be removed with stainless steel cleaner or any other similar cleaning agent NEVER use vinegar or any corrosive cleaner Use only cleaners approved for stainless steel NEVER use cleaning solvents with a hydrocarbon base NEVER use a wire brush steel or abra...

Page 8: ...8 wheel puller bolt supplied in center of hub See Fig 3 Clean The Porcelain Interior Porcelain enamel interiors are designed to be as maintenance free as possible However for best results the oven should be cleaned regularly Enameled interiors can be easily cleaned with oven cleaners KEEP CLEANING FLUIDS AWAY FROM ELECTRICAL WIRES LIGHT SOCKETS SWITCHES AND CONTROLPANEL OVEN EXTERIOR Clean The Ext...

Page 9: ... 2 13 x 1 HEX HEAD BOLT 12 REQUIRED 5 16 FLATWASHER 4 REQUIRED 5 16 18 HEX NUT 4 REQUIRED OPEN RACK SHELF RACK SUPPORT 3 8 16 x 3 4 TRUSS HEAD SCREW w NUT WASHER 8 REQUIRED 5 ILLUSTRATIONS CONTINUED CONTROL PANEL ROTARY CONTROL Figure 3 Figure 4 Figure 5 9 SELECTOR SWITCH PILOT LIGHT GREEN SELECTOR SWITCH THERMOSTAT PILOT LIGHT AMBER THERMOSTAT LIGHTS SWITCH TIMER STEAM INJECTION SWITCH ...

Page 10: ...O GC 20 NO COM L2 L1 NO NC ooox ooxo oxoo oxxo 24V 120V BUZZER TIMER M450 1 2 4 S Fan Rotary Switch Off Low High Cool Down Door Switch Solenoid Valve Amber Pilot Light Thermostat Green Pilot Light Temperature Controller Power RAM CO Power Timer Coil Steam Potentiometer Factory Set 8 Seconds Coil Steam Button Ignition Module Valve 2 Speed Motor Interior Lights Momentary Switch Interior Lights 10 ...

Page 11: ...ame sensor ground valve hot thermostat L1 24vac ignitor 3 4 5 6 2 1 7 steam switch steam timer potentiometer blk yel red blu solenoid valve FF PILOT IN 120v 24v ignitor 120VAC 1 2 3 4 S Rotary Switch Door Switch Pilot Light Thermostat Pilot Light Power RAM LO HI COM 7 WIRING DIAGRAM ROTARY CONTROL CO1 G 11 ...

Page 12: ...nsor L1 Ignitor Sensor RAM COM HI LO Door Sw NC NO Lights Switch CO VALVE 120 V Grn Ylo CH 100 FAST T12 T6 T7 T13 T9 T8 T5 T4 T3 T2 24V 120V T11 T10 RTD Probe Rotary Switch P2 P3 P4 P1 1 2 3 4 Closed Open 120 V L1 N BLK 1 WT 2 BLK 11 BLK 3 BLK 5 WT C2 WT 4 BLK S WT S2 WT S1 GREY 7 8 R1 R2 Orange Black A B BLK 13 BLUE 10 BLK C1 BLK 23 BLK 15 GREY 26 27 BLK 17 BLUE 12 BLK WT BLK 21 BLK 19 BRWN BRWN ...

Page 13: ...CE LP 12 E3149X Top Left Angle Open Rack Stand 34 R1116A Manifold 13 T3051X Left Rack Support Open Rack Stand 35 S3228A Flange Bearing 4 14 T3052X Right Rack Support Open Rack Stand 36 S3231X Door Chain Assy Complete 15 T8075X Bottom Shelf w Hdwr Open Rack Stand 37 S3226A Door Chain Rod Short 16 R3180A 48 Burner Orifice Spud Nat 38 S3227A Door Chain Rod Long 17 R3175A 57 Burner Orifice Spud LP 39 ...

Page 14: ...69 70 71 72 74 75 75 75 73 76 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 16 ER B K S A ER B K S A I P E D RI P E D R w S r i o tc o h D 93 21 21 22 22 7 7 14 CO1 G Full Size Gas Convection Oven 864 963 3471 864 963 5316 800 927 6887 customerservice bkideas com fax US Canada web address PO Box 80400 Simpsonville SC 29680 0400 BKI WORLDWIDE Note When ordering ALWAYS specify Part Model Serial Volta...

Page 15: ...ter 26 E3095X Baffle Plate Bracket Assy 4 74 M1335X Bell Audiolarm 27 Q1414A Screw Hex Hd 10x3 4 8 75 S1311X Knob 3 28 E3481X Combustion Chamber Front Center 76 M1352X Ckt Breaker 120 240V 15A 29 E3482X Combustion Chamber Front Left 77 30 E3511X Combustion Chamber Front Right 78 M1356A Solid State Relay CE 31 E3471K Door Switch Actuator 79 M1145X Transformer 120V 24V 32 M1102X Microswitch Rotary 8...

Page 16: ...ONS Negligence or acts of God Thermostat calibrations after 30 days from equipment installation date Air and Gas adjustments Light bulbs Glass doors and door adjustments Fuses Adjustments to burner flames and cleaning of pilot burners Tightening of screws or fasteners Failures caused by erratic voltages or gas supplies Unauthorized repair by anyone other than a BKI Factory Authorized Service Cente...

Reviews: