USER MANUAL AI BOX 

2.

 

Mode Button 

Mode button is used in this device is tactile switches type, user-developed operating 

script. 

3.

 

Reset Button 

The reset button is used to factory reset the device. 

Reset procedure: Unplug the Box B01 -> Hold down the reset button -> Plug in the 

power -> Continue to hold for about 10 seconds and then release it -> Box will perform a 
factory reset and boot up at the Google Setup Wizad screen 

4.

 

USB Type C 

One port USB Type C 3.1 is available in this device for debug and flashing images. 

5.

 

HDMI 

One port HDMI 1.4 Type A is available in this device for transmitting images, videos 

to external devices such as monitors. 

6.

 

Alarm I/O (DI/DO terminal) 

Various I/O supports including Alarm-in, Alarm-out (Relay). 

DI1+ 

 

1

st

   Alarm input signal line terminal, positive 

DI1- 

1

st

   Alarm input signal line terminal, negative (GND) 

DI2+ 

2

nd

  Alarm input signal line terminal, positive 

DI2- 

2

nd

  Alarm input signal line terminal, negative (GND) 

DOA 

1

st

   Alarm output signal line terminal 1  

DOB 

1

st

   Alarm output signal line terminal 2  

DOC 

2

nd

  Alarm output signal line terminal 1  

DOD 

2

nd

  Alarm output signal line terminal 2 

Two alarm outputs with NO contacts of IM06GR (TE) relay: 

 

Switching power: 60W/62.5VA 

 

Switching voltage: 220VDC/250VAC 

 

Switching current: 2A 

Two alarm inputs can support input voltage level are 5VDC to 12VDC. 

 

 