BK Radio
9
Programming Repeater Parameters
To access the DRH-01-100 repeater parameters
click the “Global” folder in the left panel.
Hang times
Hang times hold the repeater in receive and/or transmit condition after
an incoming signal has dropped. This allows radio users to respond
without the repeater toggling to standby mode.
TX Hang Time (sec)
Select the desired time for the repeater to continue transmitting after
the incoming signal has stopped. 0 to 7.5 seconds.
RX Hang Time (sec)
Select the desired time for the repeater to keep the receiver open after
the incoming signal has stopped. 0 to 7.5 seconds.
Data Preamble (msec)
The Preamble is a signal that is sent when the repeater transmitter
transitions from idle to transmitting.
Programming a Data Preamble allows time for a receiving radio to
establish reception prior to receiving incoming signals, decreasing the
chance of missing information.
The Data Preamble can be programmed from 0 to 315 msec.
Channel Selection
Use the Zone and Channel drop boxes to select the DRH-01-100
operating channel.