Model: 601B
SLA Battery Capacity Analyzer
USER MANUAL
Page 1: ...Model 601B SLA Battery Capacity Analyzer USER MANUAL...
Page 2: ...line voltage will void the warranty Make all connections to the instrument before applying power Do not operate the instrument in ways not specified by this manual or by B K Precision Failure to comp...
Page 3: ...s are meant to be connected to the mains supply at a standard wall outlet or similar sources Example measurement environments are portable tools and household appliances Category III CAT III Measureme...
Page 4: ...ffice type indoor environments Do not operate the instrument In the presence of noxious corrosive or flammable fumes gases vapors chemicals or finely divided particulates In relative humidity conditio...
Page 5: ...g magnetic fields Do not operate instrument if damaged If the instrument is damaged appears to be damaged or if any liquid chemical or other material gets on or inside the instrument remove the instru...
Page 6: ...avoid injuries always disconnect the power cord from the instrument disconnect all other connections for example test leads computer interface cables etc discharge all circuits and verify there are no...
Page 7: ...instrument to B K Precision for service and repair to ensure that safety and performance features are maintained For continued safe use of the instrument Do not place heavy objects on the instrument D...
Page 8: ...Section 1 General Description 9 1 1 INTRODUCTION 9 1 2 APPLICATIONS 9 1 3 SPECIFICATIONS 9 Section 2 Operation 10 2 1 Front Panel Controls 10 2 2 Operating Procedure 11 Service Information 14 Limited...
Page 9: ...nance will increase along with increasing demand for UPS The 601B can be applicable for Automobile Service Stations UPS Manufacturing Maintenance and Field Servicing QC Department Battery Systems in R...
Page 10: ...this key the user can decrease the Ah values 4 Test On pressing this key the measurement will begin 5 Repeat Test This key is used to repeat previously performed test 6 Reverse Polarity LED This LED...
Page 11: ...1B performs a memory test displays open circuit voltage on LCD CAUTION Do not connect the ve terminal of 601B to ve terminal of BUT and ve terminal of 601B to ve terminal of BUT On doing so the Revers...
Page 12: ...h off during the test TEST INPROGRESS 12 53V 028AH The results will be displayed as follows 12 37V 61 87 CAP IR 39 2 mOhm The first field indicates the battery terminal voltage when battery was loaded...
Page 13: ...t press SELECT Ah key in order to repeat the same test press TEST REPEAT key To prevent unnecessary discharge of BUT the unit will switch off automatically after 5 minutes of non operational period 1...
Page 14: ...s probes connectors and accessories that you are using with the device Customers not on an open account must include payment in the form of a money order or credit card For the most current repair cha...
Page 15: ...nstrument via our website www bkprecision com Exclusions This warranty does not apply in the event of misuse or abuse of the product or as a result of unauthorized alterations or repairs The warranty...
Page 16: ...irements of 2006 95 EC Low Voltage Directive and 2004 108 EC Electromagnetic Compatibility Directive with the following standards Low Voltage Directive EN61010 1 2001 EMC Directive EN61326 1 2013 CISP...
Page 17: ...17 B K Precision Corporation 22820 Savi Ranch Parkway Yorba Linda California 92887 www bkprecision com 2015 B K Precision Corporation Printed in Taiwan 120815...