3.8
INPUT TAP SELECTION FOR 230V OPERATION :
In case of 230V Mains operation please ensure that shorting links on the Tap Selector
board is changed to 230V, marked on the PCB for both Mains Transformer &
Auxilary Transformer. as per the following diagram.
TAP SELECTOR BOARD
Please make sure the input varistor is replaced by 20D 361K or equivalent for
230V Mains Operation at the Input of EMI Filter located at bottom side of the unit.
3.9
REPACKAGING FOR SHIPMENT :
To ensure safe shipment of the power supply 1794 unit, it is recommended that the
package designed for the unit be used. The original packaging material is reusable.
Be sure to attach a tag to the unit specifying the owner, and the fault observed with
a brief description.