BJM Pumps R08 Installation, Operation & Maintenance Manual Download Page 1

Version 3/2/2016 

 
 

 

 

INSTALLATION, OPERATION & MAINTENANCE MANUAL 

 

R & RX SERIES 

TOP DISCHARGE  

Electric Submersible Pumps 

 

Single Phase 

115V & 230V 
Three Phase 

230V, 460V & 575V 

 
 
 

CAST IRON 

SINGLE PHASE 

THREE PHASE 

R100 
R250 
R400 

R400D 
R400P 

R750 

R1500 
R1520 
R1530 

R08 
R15 

 

316 STAINLESS STEEL 

SINGLE PHASE 

THREE PHASE 

RX750SS 

RX1500SS 

 

RX08SS 
RX15SS 

 

 
 
Read this manual carefully before installing, operating or servicing these pump models. 
Observe all safety information. Failure to comply with instructions may result in personal 
injury and/or property damage. Please retain these instructions. 

Summary of Contents for R08

Page 1: ...THREE PHASE R100 R250 R400 R400D R400P R750 R1500 R1520 R1530 R08 R15 316 STAINLESS STEEL SINGLE PHASE THREE PHASE RX750SS RX1500SS RX08SS RX15SS Read this manual carefully before installing operating...

Page 2: ......

Page 3: ...T MAY NEED TO BE PRIMED 14 SERVICING YOUR SUBMERSIBLE PUMP 14 MAINTAINING YOUR PUMP 14 CHANGING SEAL OIL 15 EXPLODED VIEW OF R100 16 EXPLODED VIEW OF R250 R400 R400D R400P 17 EXPLODED VIEW OF R750 RX7...

Page 4: ...b site www bjmpumps com For assistance with your electric power source please contact a certified electrician Please pay attention to the following alert notifications They are used to notify operator...

Page 5: ...attempt to alter the length or repair any power cable with a splice The pump motor and pump motor and cable must be completely waterproof Damage to the pump or personal injury may result from alterat...

Page 6: ...mps distributor or BJM Pumps LLC If damaged the pump may need to be repaired before use Do not install or use the pump until appropriate action has been taken Lubrication No additional lubrication is...

Page 7: ...e pump dry for extended periods of time Refer to data sheet for minimum submersion depth for your particular model Data sheets can be obtained online at www bjmpumps com or by calling BJM Pumps LLC at...

Page 8: ...ld be counter clockwise as shown in the picture below 2 By looking from the top of the pump Since the impeller cannot be seen the best way to check the rotation is to check the kick back motion of the...

Page 9: ...anty considerations Always keep the plug end dry Note 230V single phase and 208V 230V 460V 575V three phase units do not have a plug and have to be provided separately Do not alter the length or repai...

Page 10: ...or turn the power source off generator Typical 3 phase manual control 1 TYPICAL AUTOMATIC DEWATERING INSTALLATION NOTE Maximum recommended starts should not exceed 10 times per hour AUTOMATIC OPERATI...

Page 11: ...urce turn off the breaker or turn the power source off generator INTENDED METHODS OF CONNECTION Use with approved motor control that matches motor input in full load amperes UTILLISER UN D MARREAR APP...

Page 12: ...o not remove power supply cord and strain relief or connect conduit directly to the pump Installation and checking of electrical circuits and hardware should be performed by a qualified licensed elect...

Page 13: ...g device also incorporate motor overload protection Pumps must be installed in accordance with the National Electrical Code and all applicable local codes and ordinances Pumps are not to be installed...

Page 14: ...ck 4 Pumping air Check liquid level and position of pump 5 Excessive voltage drops due to long cables 6 Three phase only pump running backwards check rotation R400D ONLY NOTE THIS UNIT MAY NEED TO BE...

Page 15: ...power cable Make sure that it is free of nicks or cuts CHANGING SEAL OIL Changing the seal oil in the R series pumps is very easy 1 Make sure that the pump cable is disconnected from the power source...

Page 16: ...16 EXPLODED VIEW OF R100...

Page 17: ...17 EXPLODED VIEW OF R250 R400 R400D R400P...

Page 18: ...18 EXPLODED VIEW OF R750 RX750SS R1500 RX1500SS R1520 R1530...

Page 19: ...19 EXPLODED VIEW OF R08 RX08SS R15 RX15SS...

Page 20: ...258 202258 202258 202258 202258 13 Mechanical Seal Buna N 202269 202259 202259 202259 202259 200501 200501 200501 200501 200501 200501 13 Mechanical Seal FKM 202260 202260 202260 202260 200500 200500...

Page 21: ...Screw for Strainer 202691 50 01 2 Screw for Bottom Plate 202689 202689 202689 203220 203220 203220 203220 203220 203220 50 01 3 Stud with Nuts R400D 202688 50 07 Screw for Suction Cover 203233 203239...

Page 22: ...al Buna N Optional 200501 200501 200501 200501 14 Lower Ball Bearing 200958 200958 200958 200958 15 Impeller Shim Kit Required 200481 200481 200480 200480 16 Pump Casing Outer 202292 202294 202292 202...

Page 23: ...202568 202568 202568 202568 50 01 2 Screw for Bottom Plate 203220 203220 203220 203220 50 07 Screw for Suction Cover 203250 203250 203250 203250 50 08 Screw for Oil Chamber Cover 203219 203219 203219...

Page 24: ...24 SINGLE PHASE WIRING DIAGRAM 115V 230V W O GOVERNOR SWITCH MODELS R100 R250 R400 R400D R400P...

Page 25: ...25 SINGLE PHASE WIRING DIAGRAM 115V 230V W GOVERNOR SWITCH MODELS R750 RX750SS R1500 RX1500SS R1520 R1530...

Page 26: ...26 THREE PHASE WIRING DIAGRAM MODELS R08 RX08SS R15 RX15SS 230V...

Page 27: ...27 THREE PHASE WIRING DIAGRAM MODELS R08 RX08SS R15 RX15SS 460V...

Page 28: ...IS EXPRESSLY AGREED THAT THIS SHALL BE THE SOLE AND EXCLUSIVE REMEDY OF BJM PUMPS LLC S DISTRIBUTORS AND CUSTOMERS UNDER NO CIRCUMSTANCES SHALL BJM PUMPS LLC BE LIABLE FOR ANY COSTS LOSS EXPENSE DAMA...

Page 29: ...29...

Page 30: ...r Condition of Cable Jacket New Good Fair Poor Rotation Direction of Impeller Rotation Use C W for clockwise CC W for counterclockwise Method used to check rotation viewed from bottom Resistance of ca...

Page 31: ...top Yes No Control Panel MFG model no Number of pumps operated by control panel NOTE At no time should hole be made in top of control panel unless proper sealing devices are utilized Short Circuit pr...

Page 32: ...hecked for leaks Yes No Do check valves operate properly Yes No Flow Does station appear to operate at proper rate Yes No Noise level Acceptable Unacceptable Comments Describe and equipment difficulti...

Page 33: ...NOTES...

Page 34: ...k of BJM Pumps LLC Copyright 2006 2013 BJM Pumps LLC All rights reserved BJM Pumps LLC 123 Spencer Plain Road PO Box 1138 Old Saybrook CT 06475 USA Phone 860 399 5937 Fax 860 399 7784 Email sales bjmp...