S-F SERIES PARTS LIST 

 

Pump Model S1500CF

Pos. No.

Part Description

Item #

01-2

Stand 

201986

05

Impeller 

202098

07

Pump Housing 

203008

08

Oil Chamber Cover

202213

08-1

O-Ring (Kit Only) 

Kit

09

Lip Seal FKM

202232

13

Mechanical Seal FKM

204240

14

Lower Ball Bearing 

200958

14-2

Lower Bearing Retainer Clip

202279

15

Impeller Shim Kit (Required)

200481

17

Rotor w/ Shaft 230V, 1PH

204111

18

Stator w/ Casing 230V, 1PH (High-Temp)

201040

19

Wire Connection Kit*

204211

20

Upper Ball Bearing

200967

21A

Oil Chamber/Motor Housing

202196

21A-1

O-Ring (Kit Only)

Kit

21B

Motor Cover Upper

202368

26

Pump Top Cover (W/ Sensor opening)

202433

26-1

O-Ring (Kit Only)

Kit

27

Power Cable w/ Gland-230V,1PH (High-Temp)

204454

27-1

O-Ring (Kit Only) 

Kit

27-2

Seal Minder Cable (High-Temp)

204455

27-2-1

O-Ring Kit Only

Kit

31D

Seal Minder Probe

202408

31E

Ground Wire w/Ring Term.

203145

32

Power Cord Line Clip / Strain Relief

203161

33

Seal Minder Cable Line Clip

203163

34

Handle / Chain Handle

202517

35

Rod Bolts 

202668

38

Discharge Nipple 3"

202534

38E 

Discharge Elbow

202558

38E-1

Gasket, Discharge Elbow FKM

203209

38F

Discharge Flange 3"

202545

38F-1

Gasket, Discharge Flange FKM

202660

50-01-2

Bolt for Strainer/Stand

203228

50-07

Screw for Oil Chamber/Motor Housing 

203228

50-08

Screw for Oil Chamber Cover

203219

50-11

Screw for Oil Fill 

203218

50-11-1

O-Ring (Kit Only)

Kit

50-12

Bolt - Suction Cover

203218

50-12-1

O-Ring (Kit Only)

Kit

50-14-2

Screw

203219

50-27

Screw for Power Cord

203216

50-27-2

Screw for Seal Minder Cable

203216

50-31E

Screw for Ground Wire

202692

50-32/50-33

Screw for Line Clip

203214

50-34

Screw for Handle

203219

50-38E

Bolt for Discharge Elbow

203255

50-38F

Bolt for Discharge Flange

203289
203197

                 O-Ring Kit - FKM 

 

Summary of Contents for FAHRENHEIT S-F Seires

Page 1: ...se 115V 230V CAST IRON SINGLE PHASE S1500C F 316 STAINLESS STEEL SINGLE PHASE SX750CSS F SX1500CSS F Read this manual carefully before installing operating or servicing these pump models Observe all s...

Page 2: ...OAT CONNECTION 12 TROUBLE SHOOTING 12 PUMP WILL NOT RUN 12 PUMP RUNS BUT DOES NOT DELIVER RATED CAPACITY 13 SERVICING YOUR SUBMERSIBLE PUMP 13 MAINTAINING YOUR PUMP 13 CHANGING SEAL OIL 13 EXPLODED VI...

Page 3: ...23 Spencer Plain Rd Old Saybrook CT 06475 USA Phone 877 256 7867 Phone 860 399 5937 Fax 860 399 7784 Information including pump data sheets and performance curves is also available on our web site www...

Page 4: ...ith a worn or damaged electric power cable Death or serious injury could occur Never attempt to alter the length or repair any power cable with a splice The pump motor and pump motor and cable must be...

Page 5: ...ing appears to be abnormal contact your BJM Pumps distributor or BJM Pumps LLC If damaged the pump may need to be repaired before use Do not install or use the pump until appropriate action has been t...

Page 6: ...ILL QUANTITY TYPE OIL IN SEAL CHAMBER MODEL U S FL OZ CC TYPE OF OIL S1500C F 7 8 230 ISO 32 NSF Food Grade Mineral Oil OIL IN SEAL CHAMBER MODEL U S FL OZ CC TYPE OF OIL SX750CSS F 10 1 300 ISO 32 NS...

Page 7: ...Pumps S F SX F Series pumps are designed to operate fully submerged Data sheets can be obtained online at www bjmpumps com or by calling BJM Pumps LLC at 860 399 5937 Do not run the pump dry Pump liq...

Page 8: ...ays to check the correct pump rotation 1 By looking at the impeller the rotation of the impeller should be counter clockwise as shown in the picture below 2 By looking from the top of the pump Since t...

Page 9: ...mes per hour All S F SX F models are provided with a 50 15 m power cable NEVER splice the power cable due to safety and warranty considerations Always keep the lead end dry Note 208V 230V 460V 575V th...

Page 10: ...r source turn off the breaker or turn the power source off generator CONTROL PANELS CONNECTION OPTIONS Use with approved motor control that matches motor input in full load amperes UTILLISER UN D MARR...

Page 11: ...11 Figure 1 SX750F 115 control Figure 2 SX750F 230 S1500F 230 and SX1500F 230 control...

Page 12: ...plied as a manual ON OFF control A wide angle float can be wired in series with the thermal sensors to allow the pumps to operate in an automatic mode See the wiring diagram provided in this manual fo...

Page 13: ...meet BJM standards MAINTAINING YOUR PUMP Pump should be disconnected from the electric power supply before proceeding to do any service or maintenance Pump should be inspected at regular intervals At...

Page 14: ...ge is needed 9 Remove the screws that hold the oil chamber cover in place remove the oil 10 Replace the mechanical seal if necessary 11 Replace the oil 12 Assemble the pump STATOR REPLACEMENT OR ELECT...

Page 15: ...15 EXPLODED VIEW OF S1500C F...

Page 16: ...16 EXPLODED VIEW OF SX750CSS F AND SX1500CSS F...

Page 17: ...04455 27 2 1 O Ring Kit Only Kit 31D Seal Minder Probe 202408 31E Ground Wire w Ring Term 203145 32 Power Cord Line Clip Strain Relief 203161 33 Seal Minder Cable Line Clip 203163 34 Handle Chain Hand...

Page 18: ...202408 31E Ground Wire w Ring Term 203145 203145 32 Power Cord Line Clip Strain Relief 203166 203166 33 Seal Minder Cable Line Clip 203163 203163 34 Handle Chain Handle 202517 202517 35 Rod Bolts 2026...

Page 19: ...19 SINGLE PHASE WIRING DIAGRAM 115V 230V MODELS S1500CF SX750CSSF SX1500CSSF...

Page 20: ...winding and allow for longer pump life The sensor cable consists of four leads two are connected to the Seal Minder and two are connected to the thermal sensor switches located in the stator windings...

Page 21: ...IS EXPRESSLY AGREED THAT THIS SHALL BE THE SOLE AND EXCLUSIVE REMEDY OF BJM PUMPS LLC S DISTRIBUTORS AND CUSTOMERS UNDER NO CIRCUMSTANCES SHALL BJM PUMPS LLC BE LIABLE FOR ANY COSTS LOSS EXPENSE DAMA...

Page 22: ...o Condition of Equipment New Good Fair Poor Condition of Cable Jacket New Good Fair Poor Rotation Direction of Impeller Rotation viewed from bottom Use C W for clockwise CC W for counterclockwise Resi...

Page 23: ...no Number of pumps operated by control panel NOTE At no time should hole be made in top of control panel unless proper sealing devices are utilized Short Circuit protection Type Number and size of sho...

Page 24: ...ump on L1 L2 L3 FINAL CHECK Is pump secured properly Yes No Was pump checked for leaks Yes No Do check valves operate properly Yes No Flow Do pumps appear to operate at proper rate Yes No Noise level...

Page 25: ...NOTES...

Page 26: ...er is a registered trademark of BJM Pumps LLC Copyright 2009 2018 BJM Pumps LLC All rights reserved BJM Pumps LLC 123 Spencer Plain Road PO Box 1138 Old Saybrook CT 06475 USA Phone 860 399 5937 Fax 86...

Reviews: