BITTNER Installation & Operations Manual
DSP
P
ROCESSOR
The Series XR amplifiers are equipped with an internal DSP processor. With the internal processor extended
functionality is available:
-
Level Control
-
Input routing of the two amplifier channels
-
10-Band Equalizer
-
Dynamics (Limiter/Compressor/Gate)
-
Delay
-
Cross-Over
-
Up to 100 stored presets
Two way of controlling the internal DSP are available:
1. the control interface BITTNER SXL, connected to the amplifier via control network
2. the DSP software installed on a computer, connected via RS-485 to the amplifier
1.1 DSP Control Interface SXL with SXL Web interface:
(See also chapter ‘SXL Data Port’.) The DSP can be controlled with the Web Interface of the BITTNER SXL
Control Interface. The amplifier must be connected to the SXL unit by ribbon cable and as the next step the
SXL unit must be connected to the controlling PC over the Ethernet control network to establish access to
the built-in-sxl web server.
When the SXL unit is addressed via Web browser, the DSP control page of the Web Interface is available
and all features of the DSP are accessible via the web interface (see image below).
The available SXL presets (settings of all amplifiers, 16 channels and SXL) are called Configurations (Cfg)
and can be saved and recalled from the SXL’s internal memory.
A signal generator is also available within the DSP functionality and can be used as pilot tone generator
(loudspeaker line test) or as test tone generator for measurements etc.
Note: Controls that are not used with the specified amplifier model are disabled i.e. not used and not available.
screen shot of the DSP control over the SXL web interface
Note: To obtain access to the SXL web interface, the user must first log-in. Default name/password is: